Literature DB >> 21804180

The ArcCHECK diode array for dosimetric verification of HybridArc.

A L Petoukhova1, J van Egmond, M G C Eenink, R G J Wiggenraad, J P C van Santvoort.   

Abstract

The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elements. HybridArc plans for various sites (intracranial and extracranial) were constructed and after that these plans were recalculated for the ArcCHECK diode array with Monte Carlo (MC) and Pencil Beam (PB) dose algorithms in iPlan RT Dose. All measurements of these HybridArc plans were performed with 6 MV photon beams of a Novalis accelerator (BrainLAB, Feldkirchen, Germany) using the ArcCHECK device without and with an insert containing an ionization chamber. Comparison of the absolute dose distributions measured and calculated in iPlan RT Dose with the MC algorithm at the cylinder of the ArcCHECK diode array for HybridArc plans gives good agreement, even for the 2% dose difference and 2 mm distance-to-agreement criteria. The PB calculations significantly differ from the ArcCHECK measurements so that the MC algorithm is found to be superior to the PB algorithm in the calculation of the HybridArc plans. One of the drawbacks of the PB calculations in iPlan RT Dose is the too large arc step size of 10°. Use of a finer angular resolution may improve the PB results significantly.

Entities:  

Mesh:

Year:  2011        PMID: 21804180     DOI: 10.1088/0031-9155/56/16/021

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  FusionArc optimization: a hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy.

Authors:  Martha M Matuszak; Jennifer M Steers; Troy Long; Daniel L McShan; Benedick A Fraass; H Edwin Romeijn; Randall K Ten Haken
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

2.  Comparison of global and local gamma evaluation results using isodose levels.

Authors:  Liting Yu; Tanya Kairn; Jamie V Trapp; Scott B Crowe
Journal:  Phys Eng Sci Med       Date:  2021-02-08

3.  Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations.

Authors:  H-J Shin; J H Song; J-Y Jung; Y-K Kwak; C S Kay; Y-N Kang; B O Choi; H S Jang; S H Son
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

4.  Dosimetric verification by using the ArcCHECK system and 3DVH software for various target sizes.

Authors:  Jin Ho Song; Hun-Joo Shin; Chul Seung Kay; Seok Hyun Son
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

5.  The Impact of Dose Rate on the Accuracy of Step-and-Shoot Intensity-modulated Radiation Therapy Quality Assurance Using Varian 2300CD.

Authors:  Christopher F Njeh; Howard W Salmon; Claire Schiller
Journal:  J Med Phys       Date:  2017 Oct-Dec

6.  Validation of an improved helical diode array and dose reconstruction software using TG-244 datasets and stringent dose comparison criteria.

Authors:  Saeed Ahmed; Benjamin Nelms; Jakub Kozelka; Geoffrey Zhang; Eduardo Moros; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

7.  Implementation of HybridArc treatment technique in preoperative radiotherapy of rectal cancer: dose patterns in target lesions and organs at risk as compared to helical Tomotherapy and RapidArc.

Authors:  Thierry Gevaert; Benedikt Engels; Cristina Garibaldi; Dirk Verellen; Peter Deconinck; Michael Duchateau; Truus Reynders; Koen Tournel; Mark De Ridder
Journal:  Radiat Oncol       Date:  2012-07-31       Impact factor: 3.481

8.  Comparison of dose calculations between pencil-beam and Monte Carlo algorithms of the iPlan RT in arc therapy using a homogenous phantom with 3DVH software.

Authors:  Jin Ho Song; Hun-Joo Shin; Chul Seung Kay; Soo-Min Chae; Seok Hyun Son
Journal:  Radiat Oncol       Date:  2013-12-05       Impact factor: 3.481

9.  Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.

Authors:  Ziyad A Alrowaili; Michael L F Lerch; Marco Petasecca; Martin G Carolan; Peter E Metcalfe; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

10.  Primo software as a tool for Monte Carlo simulations of intensity modulated radiotherapy: a feasibility study.

Authors:  Alessandro Esposito; Sofia Silva; Jorge Oliveira; Joana Lencart; João Santos
Journal:  Radiat Oncol       Date:  2018-05-15       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.