Force system evaluation of symmetrical beta-titanium T-loop springs preactivated by curvature and concentrated bends.

Sergei Godeiro Fernandes Rabelo Caldas1, Renato Parsekian Martins, Marília Regalado Galvão, Camilla Ivini Viana Vieira, Lídia Parsekian Martins.   

Abstract

INTRODUCTION: The objective of this research was to compare the effect of preactivation on the force system of beta-titanium T-loop springs (TLSs).
METHODS: Twenty TLSs with dimensions of 6 × 10 mm, of 0.017 × 0.025-in beta-titanium alloy, were randomly divided into 2 groups according to their preactivation. By using a moment transducer coupled to a digital extensometer indicator adapted to a testing machine, the amounts of horizontal force and moment produced were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation in an interbracket distance of 23 mm. The moment-to-force ratio, the "neutral position" and the load-deflection ratio were also calculated.
RESULTS: TLSs preactivated by curvature delivered horizontal forces significantly lower than those preactivated by concentrated bends. No differences were found in relation to the moments produced throughout the deactivation of both groups. The moment-to-force ratios were systematically higher on the TLSs preactivated by curvature than those preactivated by concentrated bends, except on 5 mm of activation. Significant differences were found in the load-deflection rates and "neutral position."
CONCLUSIONS: The TLSs preactivated by curvature delivered lower horizontal forces and higher moment-to-force and load-deflection ratios than did those preactivated by concentrated bends.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 21803234     DOI: 10.1016/j.ajodo.2010.11.022

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  5 in total

1.  Differences in the force system delivered by different beta-titanium wires in elaborate designs.

Authors:  Renato Parsekian Martins; Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Luís Geraldo Vaz; Roberto Hideo Shimizu; Lídia Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2015 Nov-Dec

2.  Stability of beta-titanium T-loop springs preactivated by gradual curvature.

Authors:  Sergei Godeiro Fernandes Rabelo Caldas; Renato Parsekian Martins; Marcela Emílio de Araújo; Marília Regalado Galvão; Roberto Soares da Silva Júnior; Lídia Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2017 Nov-Dec

3.  Mechanical force system of double key loop with finite element analysis.

Authors:  Jiali Liu; Duanqiang Zhang; Linyu Xu; Senxin Cai; Jinquan Guo; Jiang Chen; Jiehua Su
Journal:  BMC Oral Health       Date:  2021-06-13       Impact factor: 2.757

4.  Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loops.

Authors:  Saúl Matos de Castro; Rui Moreira; Ana Cristina Braga; Afonso Pinhão Ferreira; Maria Cristina Pollmann
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

5.  Segmented arch or continuous arch technique? A rational approach.

Authors:  Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Hallissa Simplício; André Wilson Machado
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr