Literature DB >> 21799416

Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery.

Bart F Geerts1, Jacinta Maas, Rob B P de Wilde, Leon P H J Aarts, Jos R C Jansen.   

Abstract

BACKGROUND AND
OBJECTIVE: In pharmacological research, arm occlusion pressure is used to study haemodynamic effects of drugs. However, arm occlusion pressure might be an indicator of static filling pressure of the arm. We hypothesised that arm occlusion pressure can be used to predict fluid loading responsiveness.
METHODS: Twenty-four patients who underwent cardiac surgery were studied during their first 2 h in the ICU. The lungs were ventilated mechanically and left ventricular function was supported as necessary. Arm occlusion pressure was defined as the radial artery pressure after occluding arterial flow for 35 s by a blood pressure cuff inflated to 50 mmHg above SBP. The cuff was positioned around the arm in which a radial artery catheter had been inserted. Measurements were performed before (baseline) and after fluid loading (500 ml hydroxyethyl starch 6%). Patients whose cardiac output increased by at least 10% were defined as responders.
RESULTS: In responders (n = 17), arm occlusion pressure, mean arterial pressure and central venous pressure increased and stroke volume variation and pulse pressure variation decreased. In non-responders (n = 7), arm occlusion pressure and central venous pressure increased, and pulse pressure variation decreased. Mean arterial pressure, stroke volume variation and heart rate did not change significantly. The area under the curve to predict fluid loading responsiveness for arm occlusion pressure was 0.786 (95% confidence interval 0.567-1.000), at a cut-off of 21.9 mmHg, with sensitivity of 71% and specificity of 88% in predicting fluid loading responsiveness. Prediction of responders with baseline arm occlusion pressure was as good as baseline stroke volume variation and pulse pressure variation.
CONCLUSION: Arm occlusion pressure was a good predictor of fluid loading responsiveness in our group of cardiac surgery patients and offers clinical advantages over stroke volume variation and pulse pressure variation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21799416     DOI: 10.1097/EJA.0b013e32834a67d2

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  9 in total

Review 1.  The use of the oesophageal Doppler in perioperative medicine: new opportunities in research and clinical practice.

Authors:  Bernardo Bollen Pinto; Glen Atlas; Bart F Geerts; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2016-08-27       Impact factor: 2.502

Review 2.  Venous return and mean systemic filling pressure: physiology and clinical applications.

Authors:  Romain Persichini; Christopher Lai; Jean-Louis Teboul; Imane Adda; Laurent Guérin; Xavier Monnet
Journal:  Crit Care       Date:  2022-05-24       Impact factor: 19.334

3.  Basic concepts of fluid responsiveness.

Authors:  T G V Cherpanath; B F Geerts; W K Lagrand; M J Schultz; A B J Groeneveld
Journal:  Neth Heart J       Date:  2013-12       Impact factor: 2.380

4.  Ventilator-induced pulse pressure variation in neonates.

Authors:  Linda Heskamp; Benno Lansdorp; Jeroen Hopman; Joris Lemson; Willem-Pieter de Boode
Journal:  Physiol Rep       Date:  2016-02

Review 5.  What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis.

Authors:  Laura Toscani; Hollmann D Aya; Dimitra Antonakaki; Davide Bastoni; Ximena Watson; Nish Arulkumaran; Andrew Rhodes; Maurizio Cecconi
Journal:  Crit Care       Date:  2017-08-04       Impact factor: 9.097

Review 6.  Estimating mean circulatory filling pressure in clinical practice: a systematic review comparing three bedside methods in the critically ill.

Authors:  Marije Wijnberge; Daniko P Sindhunata; Michael R Pinsky; Alexander P Vlaar; Else Ouweneel; Jos R Jansen; Denise P Veelo; Bart F Geerts
Journal:  Ann Intensive Care       Date:  2018-06-20       Impact factor: 6.925

7.  The inspiration hold maneuver is a reliable method to assess mean systemic filling pressure but its clinical value remains unclear.

Authors:  Lex M van Loon; Hans van der Hoeven; Peter H Veltink; Joris Lemson
Journal:  Ann Transl Med       Date:  2020-11

8.  Estimation of mean systemic filling pressure in postoperative cardiac surgery patients with three methods.

Authors:  Jacinta J Maas; Michael R Pinsky; Bart F Geerts; Rob B de Wilde; Jos R Jansen
Journal:  Intensive Care Med       Date:  2012-05-15       Impact factor: 17.440

Review 9.  Fluid responsiveness in acute circulatory failure.

Authors:  Ahmed Hasanin
Journal:  J Intensive Care       Date:  2015-11-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.