Literature DB >> 21793174

Transaortic transcatheter aortic valve implantation within a previous bioprosthetic aortic valve replacement.

James Cockburn1, Uday Trivedi, David Hildick-Smith.   

Abstract

This report documents the first reported case of transaortic transcatheter aortic valve implantation (TAVI) using the CoreValve ReValving system (Medtronic CoreValve System, Luxembourg), within a previous bioprosthetic aortic valve replacement. TAVI has become a recognized percutaneous treatment for patients with severe native or bioprosthetic aortic valve stenosis. However, as the number of patients screened for TAVI increases, a number of patients are found with absolutely no option for peripheral arterial access, either from the femoral or subclavian routes. Transaortic CoreValve placement offers an alternate minimally invasive hybrid surgical/interventional technique when peripheral access is not possible. A CoreValve prosthesis was implanted via the transaortic route in an 81-year-old woman with severe bioprosthetic aortic valve stenosis (21 mm Mitroflow pericardial valve, peak instantaneous gradient of 99 mmHg, effective valve orifice area (EOA) of 0.3 cm(2) , as ilio-femoral and left subclavian angiography revealed small calibre vessels (<6 mm). Access was achieved via a mini thoracotomy via the left anterior second intercostal space. The procedure went without complication. Post procedure the patient was transferred directly to the Cardiac Care Unit for recuperation. Post procedure echocardiography showed that the TAVI was well positioned with no para-valvular leak and a reduction in peak instantaneous gradient to 30 mmHg and an increase in EOA to 1.5 cm(2) . She was discharged on the third post-procedural day in sinus rhythm with a narrow QRS complex. CoreValve implantation within previous surgical bioprosthesis is now an established treatment. The transaortic approach to transcatheter implantation is a promising recent development, when due to anatomical reasons, transfemoral or subclavian TAVI is not feasible.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21793174     DOI: 10.1002/ccd.23044

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Patient selection for transcatheter aortic valve implantation: An interventional cardiology perspective.

Authors:  Darrren Mylotte; Giuseppe Martucci; Nicolo Piazza
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 2.  Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration.

Authors:  Ross M Reul; Mahesh K Ramchandani; Michael J Reardon
Journal:  Methodist Debakey Cardiovasc J       Date:  2017 Jul-Sep

3.  Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses.

Authors:  Harish Ramakrishna; Patrick A DeValeria; John P Sweeney; Farouk Mookaram
Journal:  Ann Card Anaesth       Date:  2015 Apr-Jun

4.  First ever transmitral valve in valve replacement in India.

Authors:  Praveen Chandra; Rashmi Xavier; Nagendra S Chouhan; Raj Makkar; Naresh Trehan
Journal:  Indian Heart J       Date:  2017-09-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.