Non-destructive analysis of tablet coatings with optical coherence tomography.

D M Koller1, G Hannesschläger, M Leitner, J G Khinast.   

Abstract

Optical coherence tomography (OCT) is a non-invasive analysis technique allowing fast and high-quality cross-sectional imaging of scattering media. OCT is based on the physical phenomenon of low coherence interferometry and is thus well suited to image layered structures. In this paper, high-speed spectral domain OCT was used for the characterization of pharmaceutical tablet coatings, sampled at different stages of an industrial drum spray coating process, comprising tablets with a coating thickness ranging from uncoated to a target coating thickness of about 70 μm. In addition to the OCT investigation of layer thickness and homogeneity, tablet weight gain and tablet diameters were determined on a single-tablet level. Scanning electron microscopy (SEM) was applied for referencing the coating thickness obtained with OCT. We demonstrated that OCT allows rapid evaluation of coating properties, such as thickness and homogeneity independently from variations of the tablet core. In contrast to indirect methods, deviations observed with OCT can be related directly to the coating properties. Furthermore, for an extended morphological coating characterization, three dimensional images were reconstructed. Pending further developments, the high axial resolution and fast data acquisition rate of OCT has the potential for highly accurate, fast and low-cost coating control during and after manufacturing.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21787865     DOI: 10.1016/j.ejps.2011.06.017

Source DB:  PubMed          Journal:  Eur J Pharm Sci        ISSN: 0928-0987            Impact factor:   4.384


  7 in total

1.  Supervisory control system for monitoring a pharmaceutical hot melt extrusion process.

Authors:  Daniel Markl; Patrick R Wahl; José C Menezes; Daniel M Koller; Barbara Kavsek; Kjell Francois; Eva Roblegg; Johannes G Khinast
Journal:  AAPS PharmSciTech       Date:  2013-09       Impact factor: 3.246

2.  Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle.

Authors:  Jan Philip Kolb; Thomas Klein; Corinna L Kufner; Wolfgang Wieser; Aljoscha S Neubauer; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-04-02       Impact factor: 3.732

3.  Relationship between axial resolution and signal-to-noise ratio in optical coherence tomography.

Authors:  Danielle J Harper; Benjamin J Vakoc
Journal:  Opt Lett       Date:  2022-03-15       Impact factor: 3.776

Review 4.  Solvent-free melting techniques for the preparation of lipid-based solid oral formulations.

Authors:  Karin Becker; Sharareh Salar-Behzadi; Andreas Zimmer
Journal:  Pharm Res       Date:  2015-03-19       Impact factor: 4.200

5.  Three-dimensional structure analysis and percolation properties of a barrier marine coating.

Authors:  Bo Chen; Manuel Guizar-Sicairos; Gang Xiong; Laura Shemilt; Ana Diaz; John Nutter; Nicolas Burdet; Suguo Huo; Joel Mancuso; Alexander Monteith; Frank Vergeer; Andrew Burgess; Ian Robinson
Journal:  Sci Rep       Date:  2013-01-31       Impact factor: 4.379

6.  Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation.

Authors:  Hungyen Lin; Yue Dong; Yaochun Shen; J Axel Zeitler
Journal:  J Pharm Sci       Date:  2015-06-17       Impact factor: 3.534

Review 7.  Image Analysis: A Versatile Tool in the Manufacturing and Quality Control of Pharmaceutical Dosage Forms.

Authors:  Dóra Farkas; Lajos Madarász; Zsombor K Nagy; István Antal; Nikolett Kállai-Szabó
Journal:  Pharmaceutics       Date:  2021-05-10       Impact factor: 6.321

  7 in total