Literature DB >> 2178440

Upper extremity assistive devices: assessment of use by spinal cord-injured patients with quadriplegia.

S L Garber1, T L Gregorio.   

Abstract

Upper extremity assistive devices prescribed during the rehabilitation of the patient with quadriplegia often are discarded once the patient leaves the hospital. Therefore, we conducted this study to investigate patterns of the prescription and use of such devices and satisfaction with them. An oral questionnaire was administered to 56 spinal cord-injured quadriplegic patients 1 and 2 years after their first rehabilitation experience. Although the patients had discarded 46% of the devices within the 1st year, most of these devices were inexpensive, commercially available devices or devices made by occupational therapists. The respondents' most frequently cited reasons for discarding a device were "improved physical function" and "alternative solutions found." The devices retained in use most often were the more costly orthotics such as reciprocal orthoses and ball-bearing feeders. Sixty-four percent of the devices used within the 1st year were still being used at the end of the 2nd year. Thirty-five percent of all devices prescribed during rehabilitation were still in use at the end of 2 years. The results of this study have heightened therapists' awareness of the efficacy and use of upper extremity assistive devices and have enabled them to eliminate some devices, to modify methods of instructing patients in the use of devices, and to develop alternative products.

Entities:  

Mesh:

Year:  1990        PMID: 2178440     DOI: 10.5014/ajot.44.2.126

Source DB:  PubMed          Journal:  Am J Occup Ther        ISSN: 0272-9490


  3 in total

1.  Measuring wheelchair intervention outcomes: development of the wheelchair outcome measure.

Authors:  William B Mortenson; William C Miller; Jan Miller-Pogar
Journal:  Disabil Rehabil Assist Technol       Date:  2007-09

2.  Mobile arm supports: evidence-based benefits and criteria for use.

Authors:  Michal S Atkins; Jane M Baumgarten; Yuriko Lynn Yasuda; Rodney Adkins; Robert L Waters; Pierre Leung; Philip Requejo
Journal:  J Spinal Cord Med       Date:  2008       Impact factor: 1.985

3.  Design of a 3D-printed, open-source wrist-driven orthosis for individuals with spinal cord injury.

Authors:  Alexandra A Portnova; Gaurav Mukherjee; Keshia M Peters; Ann Yamane; Katherine M Steele
Journal:  PLoS One       Date:  2018-02-22       Impact factor: 3.240

  3 in total