Literature DB >> 21782479

In vitro comparison of water displacement method and 3 Tesla MRI for MR-volumetry of the olfactory bulb: which sequence is appropriate?

Hartmut Peter Burmeister1, Constanze Möslein, Thomas Bitter, Rosemarie Fröber, Karl-Heinz Herrmann, Pascal Andreas Thomas Baltzer, Hilmar Gudziol, Matthias Dietzel, Orlando Guntinas-Lichius, Werner Alois Kaiser.   

Abstract

RATIONALE AND
OBJECTIVES: Magnetic resonance imaging olfactory bulb (OB) volumetry (OBV) is already used as a complementary prognostic tool to assess olfactory disorders. However, a reference standard in imaging for OBV has not been established. The aim of this in vitro study was to compare volumetric results of different magnetic resonance sequences for OBV at 3 T to genuine OB volumes measured by water displacement.
MATERIALS AND METHODS: The volumes of 15 human cadaveric OBs were measured using the water displacement method in this institutional review board-approved prospective study. The magnetic resonance imaging protocol at 3 T included constructive interference in steady state (CISS), T2-weighted (T2w) three-dimensional (3D) sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE), T2w two-dimensional (2D) turbo spin-echo (TSE), and T1-weighted (T1w) 3D fast low-angle shot (FLASH) sequences. Two blinded observers independently performed two OB volumetric assessments per bulbus and sequence. Intraobserver and interobserver reliabilities were assessed by intraclass correlation coefficients. Bland-Altman plots were analyzed to evaluate systematic biases and concordance correlation coefficients to assess reproducibility.
RESULTS: For both observers, intraclass correlation coefficient analysis yielded almost perfect results for intraobserver reliability (CISS, 0.94-0.98; T2w 3D SPACE, 0.93-0.98; T2w 2D TSE, 0.98-0.98; T1w 3D FLASH, 0.95-0.99). Interobserver reliability showed almost perfect agreement for all sequences (CISS, 0.98; T2w 3D SPACE, 0.89; T2w 2D TSE, 0.93; T1w 3D FLASH, 0.97). The CISS sequence yielded the highest mean concordance correlation coefficient (0.95) and the highest combination of precision (0.97) and accuracy (0.98) values. In comparison with the water displacement method, Bland-Altman analyses revealed the lowest systematic bias (-0.5%) for the CISS sequence, followed by T1w 3D FLASH (-1.3%), T2w 3D SPACE (-7.5%), and T2w 2D TSE (-10.9%) sequences.
CONCLUSIONS: Compared to the water displacement method, the CISS sequence is suited best to validly and reliably measure OB volumes because of its highest values for accuracy and precision and lowest systematic bias.
Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21782479     DOI: 10.1016/j.acra.2011.06.008

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

1.  The cisternal segment of the anterior choroidal artery: an anatomical study using magnetic resonance imaging.

Authors:  Satoshi Tsutsumi; Hideo Ono; Yukimasa Yasumoto
Journal:  Childs Nerv Syst       Date:  2017-07-11       Impact factor: 1.475

2.  The suprapineal recess of the third ventricle: an anatomic study with magnetic resonance imaging.

Authors:  Satoshi Tsutsumi; Hideo Ono; Yukimasa Yasumoto
Journal:  Surg Radiol Anat       Date:  2016-12-09       Impact factor: 1.246

3.  The third ventricle roof: an anatomical study using constructive interference in steady-state magnetic resonance imaging.

Authors:  Satoshi Tsutsumi; Hisato Ishii; Hideo Ono; Yukimasa Yasumoto
Journal:  Surg Radiol Anat       Date:  2017-07-31       Impact factor: 1.246

4.  Visualization of the cavum septi pellucidi, cavum Vergae, and cavum veli interpositi using magnetic resonance imaging.

Authors:  Satoshi Tsutsumi; Hisato Ishii; Hideo Ono; Yukimasa Yasumoto
Journal:  Surg Radiol Anat       Date:  2017-11-01       Impact factor: 1.246

5.  Visualization of the periventricular Virchow-Robin spaces with ependymal openings.

Authors:  Satoshi Tsutsumi; Hideo Ono; Hisato Ishii; Yukimasa Yasumoto
Journal:  Childs Nerv Syst       Date:  2018-04-13       Impact factor: 1.475

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.