Literature DB >> 21782050

The effect of static bone strain on implant stability and bone remodeling.

Anders Halldin1, Ryo Jimbo, Carina B Johansson, Ann Wennerberg, Magnus Jacobsson, Tomas Albrektsson, Stig Hansson.   

Abstract

Bone remodeling is a process involving both dynamic and static bone strain. Although there exist numerous studies on the effect of dynamic strain on implant stability and bone remodeling, the effect of static strain has yet to be clarified. Hence, for this purpose, the effect of static bone strain on implant stability and bone remodeling was investigated in rabbits. Based on Finite Element (FE) simulation two different test implants, with a diametrical increase of 0.15 mm (group A) and 0.05 mm (group B) creating static strains in the bone of 0.045 and 0.015 respectively, were inserted in the femur (group A) and the proximal tibia metaphysis (groups A and B respectively) of 14 rabbits to observe the biological response. Both groups were compared to control implants, with no diametrical increase (group C), which were placed in the opposite leg. At the time of surgery, the insertion torque (ITQ) was measured to represent the initial stability. The rabbits were euthanized after 24 days and the removal torque (RTQ) was measured to analyze the effect on implant stability and bone remodeling. The mean ITQ value was significantly higher for both groups A and B compared to group C regardless of the bone type. The RTQ value was significantly higher in tibia for groups A and B compared to group C while group A placed in femur presented no significant difference compared to group C. The results suggest that increased static strain in the bone not only creates higher implant stability at the time of insertion, but also generates increased implant stability throughout the observation period.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21782050     DOI: 10.1016/j.bone.2011.07.003

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  7 in total

1.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

2.  Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia.

Authors:  Omer Cohen; Zeev Ormianer; Haim Tal; Daniel Rothamel; Miron Weinreb; Ofer Moses
Journal:  Clin Oral Investig       Date:  2016-03-02       Impact factor: 3.573

3.  Simulation of the mechanical interlocking capacity of a rough bone implant surface during healing.

Authors:  Anders Halldin; Mats Ander; Magnus Jacobsson; Stig Hansson
Journal:  Biomed Eng Online       Date:  2015-05-21       Impact factor: 2.819

4.  Jawbone remodeling: a conceptual study based on Synchrotron High-resolution Tomography.

Authors:  Giovanna Iezzi; Carlo Mangano; Antonio Barone; Federico Tirone; Luigi Baggi; Giuliana Tromba; Adriano Piattelli; Alessandra Giuliani
Journal:  Sci Rep       Date:  2020-03-02       Impact factor: 4.379

5.  Hybrid Funnel Technique: A Novel Approach for Implant Site Preparation: A Pilot Study.

Authors:  Luigi Canullo; Roberta Iacono; Eduardo Pires Godoy; Andrea Punzo; Alessio Cavicchia; Francesco Gianfreda; Patrizio Bollero
Journal:  Dent J (Basel)       Date:  2022-08-25

6.  Implant stability and bone remodeling up to 84 days of implantation with an initial static strain. An in vivo and theoretical investigation.

Authors:  Anders Halldin; Yohei Jinno; Silvia Galli; Mats Ander; Magnus Jacobsson; Ryo Jimbo
Journal:  Clin Oral Implants Res       Date:  2016-01-14       Impact factor: 5.977

7.  Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial.

Authors:  Edmara T P Bergamo; Abbas Zahoui; Raúl Bravo Barrera; Salah Huwais; Paulo G Coelho; Edward Dwayne Karateew; Estevam A Bonfante
Journal:  Clin Implant Dent Relat Res       Date:  2021-05-27       Impact factor: 3.932

  7 in total