Literature DB >> 21777882

Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: a pilot study.

Eberhard Grube1, Christoph Naber, Alexandre Abizaid, Eduardo Sousa, Oscar Mendiz, Pedro Lemos, Roberto Kalil Filho, Jose Mangione, Lutz Buellesfeld.   

Abstract

OBJECTIVES: The purpose of this pilot study was to evaluate the feasibility and safety of transcatheter aortic valve implantation (TAVI) without balloon pre-dilation.
BACKGROUND: Balloon pre-dilation of the stenosed aortic valve is currently believed to be a necessary step for valve preparation before device placement in patients undergoing TAVI and, therefore, is considered an obligatory part of the procedure. However, clear evidence supporting this policy is lacking. In contrast, pre-dilation might be responsible in part for distal embolizations as well as atrioventricular conduction disturbances seen during TAVI procedures.
METHODS: A total of 60 consecutive patients (mean age 80.1 ± 6.4 years, 53% female, mean logistic EuroScore 23.3 ± 15.2%) undergoing TAVI using the self-expanding Medtronic CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) have been prospectively enrolled at 13 international centers.
RESULTS: Pre-procedural mean transaortic valve gradient was 47.8 ± 15.5 mm Hg, mean effective orifice area was 0.67 ± 0.15 cm(2). Technical success rate was 96.7% (58 of 60) of patients. Post-dilation was performed in 16.7% (10 of 60) of patients. Post-procedural mean valve gradient was 4.4 ± 2.0 mm Hg. Circular and noncircular valve configuration was present in 41 and 19 cases (68.3% vs. 31.7%), respectively, with similar effective orifice areas (1.74 ± 0.10 cm(2) vs. 1.71 ± 0.22 cm(2), p = NS). In-hospital mortality, myocardial infarction, stroke, and major vascular complications occurred in 6.7% (4 of 60), 0%, 5%, and 10% of patients. There was no valve embolization. New permanent pacing was needed in 11.7% (7 of 60) of patients.
CONCLUSIONS: Transcatheter aortic valve implantation without balloon pre-dilation is feasible and safe, resulting in similar acute safety and efficacy as the current standard approach of TAVI with pre-dilation.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21777882     DOI: 10.1016/j.jcin.2011.03.015

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  36 in total

Review 1.  Current developments in transcatheter aortic valve implantation techniques.

Authors:  M Thielmann; P Kahlert; T Konorza; R Erbel; H Jakob; D Wendt
Journal:  Herz       Date:  2011-12       Impact factor: 1.443

2.  Transfemoral TAVI without pre-dilatation using balloon-expandable devices: a case-matched analysis.

Authors:  Lenard Conradi; Andreas Schaefer; Moritz Seiffert; Johannes Schirmer; Ulrich Schaefer; Gerhard Schön; Stefan Blankenberg; Hermann Reichenspurner; Hendrik Treede; Patrick Diemert
Journal:  Clin Res Cardiol       Date:  2015-03-01       Impact factor: 5.460

Review 3.  Transcatheter aortic valve implantation in Germany.

Authors:  Won-Keun Kim; Christian W Hamm
Journal:  Clin Res Cardiol       Date:  2018-06-27       Impact factor: 5.460

4.  Hotline update of clinical trials and registries presented at the 77th spring meeting of the German Society of Cardiology 2011.

Authors:  J M Sinning; K Walenta; N Werner; M Böhm
Journal:  Clin Res Cardiol       Date:  2011-06-09       Impact factor: 5.460

5.  Influence of continuously evolving transcatheter aortic valve implantation technology on cerebral oxygenation.

Authors:  Ward Eertmans; Cornelia Genbrugge; Tom Fret; Maud Beran; Kim Engelen; Herbert Gutermann; Margot Vander Laenen; Willem Boer; Bert Ferdinande; Frank Jans; Jo Dens; Cathy De Deyne
Journal:  J Clin Monit Comput       Date:  2016-12-26       Impact factor: 2.502

Review 6.  TAVI 2012: state of the art.

Authors:  Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

Review 7.  Clinical implications of conduction abnormalities and arrhythmias after transcatheter aortic valve implantation.

Authors:  Robert M A van der Boon; Patrick Houthuizen; Rutger-Jan Nuis; Nicolas M van Mieghem; Frits Prinzen; Peter P T de Jaegere
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 8.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 9.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

Review 10.  Transcatheter aortic valve replacement: current application and future directions.

Authors:  Amir-Ali Fassa; Dominique Himbert; Alec Vahanian
Journal:  Curr Cardiol Rep       Date:  2013-04       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.