Quantitative computed tomography-assisted osteodensitometry of the pelvis after press-fit cup fixation: a prospective ten-year follow-up.

Alexander M Kress1, Rainer Schmidt, Tobias Vogel, Tobias E Nowak, Raimund Forst, Lutz A Mueller.   

Abstract

BACKGROUND: As a follow-up of a previously reported three-year study, we analyzed the periprosthetic acetabular cortical and cancellous bone density changes at ten years after implantation of a press-fit cup.
METHODS: Prospective clinical, radiographic, and quantitative computed tomography examinations were performed within ten days and at mean periods of one, three, and ten years after total hip arthroplasty with a press-fit cup, a femoral stem with a tapered design, and alumina-alumina pairing. Periacetabular cortical and cancellous bone density (mg CaHA/mL) in the cranial, ventral, and dorsal regions about the cup were measured for twenty-four hips in vivo.
RESULTS: All acetabular cups showed radiographic signs of stable ingrowth, and no acetabular component had to be revised. The loss of periacetabular cancellous bone density about the cup was as much as -37% cranially, -60% ventrally, and -71% dorsally; the decrease was progressive between the one-year and three-year examinations only. In contrast, cortical bone density above the dome of the acetabular cup remained constant throughout the ten-year follow-up. A moderate change in cortical bone density of -5% to -18% was seen at the level of the cup ten years postoperatively.
CONCLUSIONS: Both periacetabular cortical and cancellous bone density changes were nonprogressive between the three-year and ten-year examinations after press-fit cup fixation.

Entities:  

Mesh:

Year:  2011        PMID: 21776552     DOI: 10.2106/JBJS.J.01097

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  Proximal tibial bone density is preserved after unicompartmental knee arthroplasty.

Authors:  Bradley I Richmond; Simon V Hadlow; Tim G Lynskey; Cameron G Walker; Jacob T Munro
Journal:  Clin Orthop Relat Res       Date:  2013-01-17       Impact factor: 4.176

2.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup: a porcine ex-vivo study using single- and dual-energy computed tomography.

Authors:  Bo Mussmann; Søren Overgaard; Trine Torfing; Morten Bøgehøj; Oke Gerke; Poul Erik Andersen
Journal:  Acta Radiol Open       Date:  2017-07-14

4.  10-year results of the uncemented Allofit press-fit cup in young patients.

Authors:  Marcus R Streit; Stefan Weiss; Franziska Andreas; Thomas Bruckner; Tilman Walker; J Philippe Kretzer; Volker Ewerbeck; Christian Merle
Journal:  Acta Orthop       Date:  2014-05-30       Impact factor: 3.717

5.  Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty.

Authors:  Dean F M Pakvis; Petra J C Heesterbeek; Marianne Severens; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-09-23       Impact factor: 3.717

6.  Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study.

Authors:  Bo Mussmann; Poul Erik Andersen; Trine Torfing; Søren Overgaard
Journal:  Acta Radiol Open       Date:  2018-08-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.