Literature DB >> 21775792

Variability of a peripheral dose among various linac geometries for second cancer risk assessment.

A Joosten1, F Bochud, S Baechler, F Levi, R-O Mirimanoff, R Moeckli.   

Abstract

Second cancer risk assessment for radiotherapy is controversial due to the large uncertainties of the dose-response relationship. This could be improved by a better assessment of the peripheral doses to healthy organs in future epidemiological studies. In this framework, we developed a simple Monte Carlo (MC) model of the Siemens Primus 6 MV linac for both open and wedged fields that we then validated with dose profiles measured in a water tank up to 30 cm from the central axis. The differences between the measured and calculated doses were comparable to other more complex MC models and never exceeded 50%. We then compared our simple MC model with the peripheral dose profiles of five different linacs with different collimation systems. We found that the peripheral dose between two linacs could differ up to a factor of 9 for small fields (5 × 5 cm2) and up to a factor of 10 for wedged fields. Considering that an uncertainty of 50% in dose estimation could be acceptable in the context of risk assessment, the MC model can be used as a generic model for large open fields (≥10 × 10 cm2) only. The uncertainties in peripheral doses should be considered in future epidemiological studies when designing the width of the dose bins to stratify the risk as a function of the dose.

Entities:  

Mesh:

Year:  2011        PMID: 21775792     DOI: 10.1088/0031-9155/56/16/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Reconstruction of organ dose for external radiotherapy patients in retrospective epidemiologic studies.

Authors:  Choonik Lee; Jae Won Jung; Christopher Pelletier; Anil Pyakuryal; Stephanie Lamart; Jong Oh Kim; Choonsik Lee
Journal:  Phys Med Biol       Date:  2015-02-26       Impact factor: 3.609

2.  Calculating and estimating second cancer risk from breast radiotherapy using Monte Carlo code with internal body scatter for each out-of-field organ.

Authors:  Takeshi Takata; Kenshiro Shiraishi; Shinobu Kumagai; Norikazu Arai; Takenori Kobayashi; Hiroshi Oba; Takahide Okamoto; Jun'ichi Kotoku
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.102

3.  Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients.

Authors:  Matthew M Mille; Jae Won Jung; Choonik Lee; Gleb A Kuzmin; Choonsik Lee
Journal:  J Radiol Prot       Date:  2018-04-11       Impact factor: 1.394

Review 4.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

5.  Breaking bad IMRT QA practice.

Authors:  Strahinja Stojadinovic; Luo Ouyang; Xuejun Gu; Arnold Pompoš; Qinan Bao; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study.

Authors:  Mikaeil Molazadeh; Ahad Zeinali; Mostafa Robatjazi; Alireza Shirazi; Ghazale Geraily
Journal:  J Appl Clin Med Phys       Date:  2017-03-06       Impact factor: 2.102

Review 7.  Cancer risk assessment in modern radiotherapy workflow with medical big data.

Authors:  Fu Jin; Huan-Li Luo; Juan Zhou; Ya-Nan He; Xian-Feng Liu; Ming-Song Zhong; Han Yang; Chao Li; Qi-Cheng Li; Xia Huang; Xiu-Mei Tian; Da Qiu; Guang-Lei He; Li Yin; Ying Wang
Journal:  Cancer Manag Res       Date:  2018-06-22       Impact factor: 3.989

8.  Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter.

Authors:  M Behmadi; H Gholamhosseinian; M Mohammadi; Sh Naseri; M Momennezhad; Sh Bayani; M T Bahreyni Toossi
Journal:  J Biomed Phys Eng       Date:  2019-04-01

9.  Exposure of remote organs and associated cancer risks from tangential and multi-field breast cancer radiotherapy.

Authors:  C Simonetto; H Rennau; J Remmele; S Sebb; P Kundrát; M Eidemüller; U Wolf; G Hildebrandt
Journal:  Strahlenther Onkol       Date:  2018-10-22       Impact factor: 3.621

10.  Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

Authors:  Vikneswary Batumalai; Alexandra Quinn; Michael Jameson; Geoff Delaney; Lois Holloway
Journal:  J Med Radiat Sci       Date:  2015-01-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.