Literature DB >> 21768752

Dose gradient analyses in Linac-based intracranial stereotactic radiosurgery using Paddick's gradient index: consideration of the optimal method for plan evaluation.

Kazuhiro Ohtakara1, Shinya Hayashi, Hiroaki Hoshi.   

Abstract

The objective of our study was to describe the dose gradient characteristics of Linac-based stereotactic radiosurgery using Paddick's gradient index (GI) and to elucidate the factors influencing the GI value. Seventy-three plans for brain metastases using the dynamic conformal arcs were reviewed. The GI values were calculated at the 80% and 90% isodose surfaces (IDSs) and at the different target coverage IDSs (D99, D95, D90, and D85). The GI values significantly decreased as the target coverage of the reference IDS increased (the percentage of the IDS decreased). There was a significant inverse correlation between the GI values and target volume. The plans generated with the addition of a 1-mm leaf margin had worse GI values both at the D99 and D95 relative to those without leaf margin. The number and arrangement of arcs also affected the GI value. The GI values are highly sensitive to (1) the IDS selection variability for dose prescription or evaluation, (2) the target volume, and (3) the planning method. To objectively compare the quality of dose gradient between rival plans, it would be preferable to employ the GI defined at the reference IDS indicating the specific target coverage (e.g., D95), irrespective of the intended marginal dose. The modified GI (mGI), defined in this study, substituting the denominator of the original GI with the target volume, would be useful to compensate for the false superior GI value in cases of target over-coverage with the reference IDS and to objectively evaluate the dose gradient outside the target boundary.

Entities:  

Mesh:

Year:  2011        PMID: 21768752     DOI: 10.1269/jrr.11005

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  13 in total

1.  Clinical outcomes of single or oligo-fractionated stereotactic radiotherapy for head and neck tumors using micromultileaf collimator-based dynamic conformal arcs.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Keisuke Mizuta; Mitsuhiro Aoki; Kenichi Ando; Sunaho Okada; Yatsuji Ito; Hiroaki Hoshi
Journal:  J Cancer Res Clin Oncol       Date:  2012-04-22       Impact factor: 4.553

2.  Consideration of optimal isodose surface selection for target coverage in micro-multileaf collimator-based stereotactic radiotherapy for large cystic brain metastases: comparison of 90%, 80% and 70% isodose surface-based planning.

Authors:  K Ohtakara; S Hayashi; H Tanaka; H Hoshi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

3.  Cerebral cyst formation following stereotactic ablative irradiation for non-nasopharyngeal head and neck malignancies: imaging findings and relevant dosimetric parameters.

Authors:  K Ohtakara; H Hoshi
Journal:  Br J Radiol       Date:  2014-02-26       Impact factor: 3.039

4.  Investigation of two linear accelerator head designs for treating brain metastases with hypofractionated volumetric-modulated arc radiotherapy.

Authors:  Mark Ruschin; Arjun Sahgal; Sara Iradji; Hany Soliman; Claudia Leavens; Young Lee
Journal:  Br J Radiol       Date:  2016-04-13       Impact factor: 3.039

5.  Determining normal tissue dose in intracranial stereotactic radiosurgery: A diameter-based predictive nomogram.

Authors:  Donal Cummins; Siobhra O'Sullivan; Mary Dunne; Ronan McDermott; Maeve Keys; David Fitzpatrick; Clare Faul; Mohsen Javadpour; Christina Skourou
Journal:  J Radiosurg SBRT       Date:  2020

6.  Hybrid planning techniques for hypofractionated whole-breast irradiation using flattening filter-free beams.

Authors:  Karunakaran Balaji; Sitaraman Balaji Subramanian; Krishnamoorthi Sathiya; Moorthi Thirunavukarasu; Chandrasekaran Anu Radha; Velayudham Ramasubramanian
Journal:  Strahlenther Onkol       Date:  2019-12-20       Impact factor: 3.621

7.  The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique.

Authors:  Xiaoyu Duan; William Giles; John P Kirkpatrick; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2019

8.  Prescription to 50-75% isodose line may be optimum for linear accelerator based radiosurgery of cranial lesions.

Authors:  Bo Zhao; Jian-Yue Jin; Ning Wen; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014

9.  Gamma Knife and volumetric modulated arc therapy stereotactic radiosurgery plan quality and OAR sparing comparison for pituitary adenomas and vestibular schwannomas.

Authors:  Salim Balik; Samuel Chao; Gennady Neyman
Journal:  J Radiosurg SBRT       Date:  2018

10.  The surface area effect: How the intermediate dose spill depends on the PTV surface area in SRS.

Authors:  Dharmin D Desai; E L Johnson; Ivan L Cordrey
Journal:  J Appl Clin Med Phys       Date:  2021-02-17       Impact factor: 2.102