Literature DB >> 21766058

The PhysioNet/Computing in Cardiology Challenge 2010: Mind the Gap.

George B Moody1.   

Abstract

Participants in the 11th annual PhysioNet/CinC Challenge were asked to reconstruct, using any combination of available prior and concurrent information, 30-second segments of ECG, continuous blood pressure waveforms, respiration, and other signals that had been removed from recordings of patients in intensive care units.Fifteen of the 53 participants provided reconstructions for the entire test set of 100 ten-minute recordings. The mean correlation between the segments that had been removed (the "target signals") and the reconstructions produced using the two most successful methods is 0.9, and the sum of the squared residual errors in these reconstructions is less than 20% of the energy of the target signals.Sources for the most successful methods developed for this challenge have been made available by their authors to support research on robust estimation of parameters derived from unreliable signals, detection of changes in patient state, and recognition of signal corruption.

Entities:  

Year:  2010        PMID: 21766058      PMCID: PMC3136865     

Source DB:  PubMed          Journal:  Comput Cardiol (2010)        ISSN: 2325-887X


  3 in total

1.  PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals.

Authors:  A L Goldberger; L A Amaral; L Glass; J M Hausdorff; P C Ivanov; R G Mark; J E Mietus; G B Moody; C K Peng; H E Stanley
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  PhysioNet 2010 Challenge: A Robust Multi-Channel Adaptive Filtering Approach to the Estimation of Physiological Recordings.

Authors:  Ikaro Silva
Journal:  Comput Cardiol (2010)       Date:  2010

3.  MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring.

Authors:  M Saeed; C Lieu; G Raber; R G Mark
Journal:  Comput Cardiol       Date:  2002
  3 in total
  5 in total

1.  A unified procedure for detecting, quantifying, and validating electrocardiogram T-wave alternans.

Authors:  H Naseri; H Pourkhajeh; M R Homaeinezhad
Journal:  Med Biol Eng Comput       Date:  2013-05-22       Impact factor: 2.602

2.  Signal quality estimation with multichannel adaptive filtering in intensive care settings.

Authors:  Ikaro Silva; Joon Lee; Roger G Mark
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-14       Impact factor: 4.538

3.  Non-invasive detection of intracranial hypertension using a simplified intracranial hemo- and hydro-dynamics model.

Authors:  Kwang Jin Lee; Chanki Park; Jooyoung Oh; Boreom Lee
Journal:  Biomed Eng Online       Date:  2015-05-30       Impact factor: 2.819

4.  Accessing the public MIMIC-II intensive care relational database for clinical research.

Authors:  Daniel J Scott; Joon Lee; Ikaro Silva; Shinhyuk Park; George B Moody; Leo A Celi; Roger G Mark
Journal:  BMC Med Inform Decis Mak       Date:  2013-01-10       Impact factor: 2.796

5.  Augmentation of Dispersion Entropy for Handling Missing and Outlier Samples in Physiological Signal Monitoring.

Authors:  Evangelos Kafantaris; Ian Piper; Tsz-Yan Milly Lo; Javier Escudero
Journal:  Entropy (Basel)       Date:  2020-03-11       Impact factor: 2.738

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.