Literature DB >> 21765870

PillCam COLON capsule endoscopy: recent advances and new insights.

Samuel N Adler1, Yoav C Metzger.   

Abstract

Capsule endoscopy for the colon was introduced to allow an alternative screening method to the invasive classic colonoscopy. The results of initial studies have shown inferior detection rates of colonic polyps by the colon capsule. In this paper we aim to review and summarize the recent advances in wireless capsule endoscopy of the colon. Publications regarding the use of colon capsule with new technology, as well as personal experience, were reviewed. Since the introduction of the first generation of the colon capsule, many improvements have been made to create a better capsule endoscope. These include a wider angle of view, a faster adaptable frame rate and a new data recorder which is able to control the capsule activity during the transit through the bowel. Recent studies show these improvements had a direct effect on the colon capsule performance, leading to a better diagnostic yield. Recent advancements in the technology of the wireless colon capsule endoscope offer the option to screen patients for colonic polyps noninvasively. Colon capsule endoscopy may become relevant for assessment of extent of inflammatory bowel disease.

Entities:  

Keywords:  CRC screening; capsule endoscopy; imaging innovations; performance; technical aspects

Year:  2011        PMID: 21765870      PMCID: PMC3131168          DOI: 10.1177/1756283X11401645

Source DB:  PubMed          Journal:  Therap Adv Gastroenterol        ISSN: 1756-283X            Impact factor:   4.409


  11 in total

1.  Wireless capsule endoscopy.

Authors:  G Iddan; G Meron; A Glukhovsky; P Swain
Journal:  Nature       Date:  2000-05-25       Impact factor: 49.962

2.  History and development of capsule endoscopy.

Authors:  Gavriel J Iddan; C Paul Swain
Journal:  Gastrointest Endosc Clin N Am       Date:  2004-01

3.  Cost-effectiveness of capsule endoscopy in screening for colorectal cancer.

Authors:  C Hassan; A Zullo; S Winn; S Morini
Journal:  Endoscopy       Date:  2008-02-27       Impact factor: 10.093

4.  Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study.

Authors:  R Eliakim; Z Fireman; I M Gralnek; K Yassin; M Waterman; Y Kopelman; J Lachter; B Koslowsky; S N Adler
Journal:  Endoscopy       Date:  2006-10       Impact factor: 10.093

5.  Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies.

Authors:  D K Rex; C S Cutler; G T Lemmel; E Y Rahmani; D W Clark; D J Helper; G A Lehman; D G Mark
Journal:  Gastroenterology       Date:  1997-01       Impact factor: 22.682

6.  Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies.

Authors:  D Heresbach; T Barrioz; M G Lapalus; D Coumaros; P Bauret; P Potier; D Sautereau; C Boustière; J C Grimaud; C Barthélémy; J Sée; I Serraj; P N D'Halluin; B Branger; T Ponchon
Journal:  Endoscopy       Date:  2008-04       Impact factor: 10.093

7.  Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy.

Authors:  R Eliakim; K Yassin; Y Niv; Y Metzger; J Lachter; E Gal; B Sapoznikov; F Konikoff; G Leichtmann; Z Fireman; Y Kopelman; S N Adler
Journal:  Endoscopy       Date:  2009-12-04       Impact factor: 10.093

8.  Capsule endoscopy versus colonoscopy for the detection of polyps and cancer.

Authors:  André Van Gossum; Miguel Munoz-Navas; Miguel Munoz Navas; Iñaqui Fernandez-Urien; Cristina Carretero; Gérard Gay; Michel Delvaux; Marie Georges Lapalus; Thierry Ponchon; Horst Neuhaus; Michael Philipper; Guido Costamagna; Maria Elena Riccioni; Cristiano Spada; Lucio Petruzziello; Chris Fraser; Aymer Postgate; Aine Fitzpatrick; Friedrich Hagenmuller; Martin Keuchel; Nathalie Schoofs; Jacques Devière
Journal:  N Engl J Med       Date:  2009-07-16       Impact factor: 91.245

9.  Colonoscopic miss rates for right-sided colon cancer: a population-based analysis.

Authors:  Brian Bressler; Lawrence F Paszat; Christopher Vinden; Cindy Li; Jingsong He; Linda Rabeneck
Journal:  Gastroenterology       Date:  2004-08       Impact factor: 22.682

10.  Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: Results of a pilot study.

Authors:  Blair S Lewis; Paul Swain
Journal:  Gastrointest Endosc       Date:  2002-09       Impact factor: 9.427

View more
  8 in total

1.  Accuracy and safety of second-generation PillCam COLON capsule for colorectal polyp detection.

Authors:  Cristiano Spada; Fabio De Vincentis; Paola Cesaro; Cesare Hassan; Maria Elena Riccioni; Leonardo Minelli Grazioli; Santiago Bolivar; Andrade Zurita; Guido Costamagna
Journal:  Therap Adv Gastroenterol       Date:  2012-05       Impact factor: 4.409

Review 2.  Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

Authors:  Silvia C Tapia-Siles; Stuart Coleman; Alfred Cuschieri
Journal:  Surg Endosc       Date:  2015-06-20       Impact factor: 4.584

Review 3.  Video capsule endoscopy in inflammatory bowel disease.

Authors:  Paul D Collins
Journal:  World J Gastrointest Endosc       Date:  2016-07-25

4.  Colon capsule endoscopy: detection of colonic polyps compared with conventional colonoscopy and visualization of extracolonic pathologies.

Authors:  Alexander F Hagel; Erwin Gäbele; Martin Raithel; Wolfgang H Hagel; Heinz Albrecht; Thomas M de Rossi; Christine Singer; Thomas Schneider; Markus F Neurath; Michael J Farnbacher
Journal:  Can J Gastroenterol Hepatol       Date:  2014-02

Review 5.  Small Bowel Dysmotility, Pseudoobstruction, and Functional Correlation with Histopathology: Lessons Learned.

Authors:  Zorisadday Gonzalez; Richard McCallum
Journal:  Curr Gastroenterol Rep       Date:  2020-02-20

Review 6.  Bowel preparation regimens for colon capsule endoscopy: a review.

Authors:  Shashideep Singhal; Sofia Nigar; Vani Paleti; Devin Lane; Sushil Duddempudi
Journal:  Therap Adv Gastroenterol       Date:  2014-05       Impact factor: 4.409

7.  A hydraulically driven colonoscope.

Authors:  Stuart A Coleman; Silvia C Tapia-Siles; Markus Pakleppa; Jan B Vorstius; Robert P Keatch; Benjie Tang; Alfred Cuschieri
Journal:  Surg Endosc       Date:  2016-07-22       Impact factor: 4.584

8.  Passive Wireless Pressure Sensing for Gastric Manometry.

Authors:  Alexander Benken; Yogesh Gianchandani
Journal:  Micromachines (Basel)       Date:  2019-12-10       Impact factor: 2.891