Literature DB >> 21763811

An ultrasensitive hydrogen peroxide biosensor based on electrocatalytic synergy of graphene-gold nanocomposite, CdTe-CdS core-shell quantum dots and gold nanoparticles.

Zhiguo Gu1, Shuping Yang, Zaijun Li, Xiulan Sun, Guangli Wang, Yinjun Fang, Junkang Liu.   

Abstract

We first reported an ultrasensitive hydrogen peroxide biosensor in this work. The biosensor was fabricated by coating graphene-gold nanocomposite (G-AuNP), CdTe-CdS core-shell quantum dots (CdTe-CdS), gold nanoparticles (AuNPs) and horseradish peroxidase (HRP) in sequence on the surface of gold electrode (GE). Cyclic voltammetry and differential pulse voltammetry were used to investigate electrochemical performances of the biosensor. Since promising electrocatalytic synergy of G-AuNP, CdTe-CdS and AuNPs towards hydrogen peroxide was achieved, the biosensor displayed a high sensitivity, low detection limit (S/N=3) (3.2×10(-11) M), wide calibration range (from 1×10(-10) M to 1.2×10(-8) M) and good long-term stability (20 weeks). Moreover, the effects of omitting G-AuNP, CdTe-CdS and AuNP were also examined. It was found that sensitivity of the biosensor is more 11-fold better if G-AuNP, CdTe-CdS and AuNPs are used. This could be ascribed to improvement of the conductivity between graphene nanosheets in the G-AuNP due to introduction of the AuNPs, ultrafast charge transfer from CdTe-CdS to the graphene sheets and AuNP due to unique electrochemical properties of the CdTe-CdS, and good biocompatibility of the AuNPs for horseradish peroxidase. The biosensor is of best sensitivity in all hydrogen peroxide biosensors based on graphene and its composites up to now.
Copyright © 2011. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21763811     DOI: 10.1016/j.aca.2011.06.015

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  3D-Printed Fluidic Devices for Nanoparticle Preparation and Flow-Injection Amperometry Using Integrated Prussian Blue Nanoparticle-Modified Electrodes.

Authors:  Gregory W Bishop; Jennifer E Satterwhite; Snehasis Bhakta; Karteek Kadimisetty; Kelsey M Gillette; Eric Chen; James F Rusling
Journal:  Anal Chem       Date:  2015-05-01       Impact factor: 6.986

Review 2.  Graphene, an Interesting Nanocarbon Allotrope for Biosensing Applications: Advances, Insights, and Prospects.

Authors:  Farid Menaa; Yazdian Fatemeh; Sandeep K Vashist; Haroon Iqbal; Olga N Sharts; Bouzid Menaa
Journal:  Biomed Eng Comput Biol       Date:  2021-02-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.