Literature DB >> 21757820

Impact of pacing and high-pass filter settings on ventricular bipolar electrograms in implantable cardioverter defibrillator systems. - Implication of predictors for inappropriate therapy caused by oversensing of repolarization electrograms-.

Akira Maesato1, Satoshi Higa, Yenn-Jiang Lin, Ichiro Chinen, Sugako Ishigaki, Machiko Yajima, Hiroaki Masuzaki, Shih-Ann Chen.   

Abstract

BACKGROUND: Predictors of T wave oversensing with implantable cardioverter-defibrillator (ICD) systems remains to be clarified. METHODS AND
RESULTS: Thirteen consecutive patients who underwent ICD implantations were included. The depolarization (R) and repolarization (T) of bipolar electrograms during baseline, AAI and DDD modes, and an isoproterenol (ISO) infusion were evaluated. The R wave amplitude during DDD was significantly lower as compared to that during the other conditions in all high-pass filter settings. In contrast, there was no significant difference in the T wave amplitude during the DDD as compared to the other conditions. With the DDD, there was a significantly higher incidence of a T/R ratio of greater than 0.25 as compared to that with the other conditions. T wave amplitude in Brugada syndrome was significantly higher than that in non-Brugada syndrome. The existence of Brugada syndrome and T/R ratio during the AAI with a high-pass filter setting of 10/20 Hz was an excellent predictor of T wave oversensing in the follow-up period.
CONCLUSIONS: DDD had a significant impact on the R wave amplitude reduction and the T/R ratio during AAI can be predictors of T wave oversensing. These findings have important implications for inappropriate shocks due to T wave oversensing.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21757820     DOI: 10.1253/circj.cj-11-0200

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

1.  T Wave Safety Margin during the Process of ICD Implantation As a Novel Predictor of T Wave Oversensing.

Authors:  Ya-Xun Sun; Jing Gao; Chen-Yang Jiang; Yu-Mei Xue; Yi-Zhou Xu; Gang Liu; Ji-Hong Guo; Xia Sheng; Yang Ye; Hong He; Yun-Tao Zhao; Hector Barajas-Martinez; Guo-Sheng Fu; Dan Hu
Journal:  Front Physiol       Date:  2017-09-01       Impact factor: 4.566

2.  Development of ventricular fibrillation after implantation of a biventricular implantable cardioverter defibrillator: what is the mechanism?

Authors:  Diego Chemello; Fernando Pivatto Júnior; Maurício Pimentel; Leandro Zimerman
Journal:  Clin Case Rep       Date:  2017-06-02

3.  Impact of a novel algorithm designed to reduce T-wave oversensing with the subcutaneous defibrillator in a patient with type I Brugada electrocardiogram.

Authors:  Serge Boveda; Marijke C Laarakker; Christèle Cardin; Jean-Paul Albenque
Journal:  HeartRhythm Case Rep       Date:  2017-11-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.