Literature DB >> 21750240

An investigation into the mechanical characteristics of select self-ligated brackets at a series of clinically relevant maximum torquing angles: loading and unloading curves and bracket deformation.

Thomas W Major1, Jason P Carey, David S Nobes, Giseon Heo, Garrett W Melenka, Paul W Major.   

Abstract

Edgewise orthodontic treatment utilizes a force couple in order to achieve labial-lingual tooth angulation. Two self-ligating brackets (Damon Q and Speed) were examined across a range of clinically relevant torques in order to assess the loading and unloading curves and bracket deformation. A previously developed torquing and load measurement system was utilized to rotate a 0.199 × 0.25 in stainless steel wire in a fixed bracket slot to the following angles: 16, 20, 24, 28, 32, and 40 degrees. The torque on the bracket was measured during both wire loading and unloading cycles. The torque play for the Damon brackets was determined to increase by less than 0.4 degrees when torqued to 70 Nmm, whereas the increase for the Speed brackets was 2.1 degrees at the same torque magnitude. The deformation curves for the Damon and Speed brackets were found to be different for loading and unloading. Speed brackets were found to start to plastically deform when torqued to 24 degrees (26 Nmm of torque), while Damon brackets did not plastically deform until 28 degrees (38 Nmm of torque). Damon brackets were found not to plastically deform as easily and to have a smaller increase in torque play than Speed brackets. Both the Damon and the Speed brackets demonstrated minimal effect of plastic deformation and torque play at maximum angles of twist less than 20 degrees. Torque measured in the brackets was different for loading and unloading.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21750240     DOI: 10.1093/ejo/cjr076

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  Torque efficiency of different archwires in 0.018- and 0.022-inch conventional brackets.

Authors:  Iosif Sifakakis; Nikolaos Pandis; Margarita Makou; Theodore Eliades; Christos Katsaros; Christoph Bourauel
Journal:  Angle Orthod       Date:  2013-05-16       Impact factor: 2.079

2.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

3.  Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

Authors:  Spyridon N Papageorgiou; Iosif Sifakakis; Ioannis Doulis; Theodore Eliades; Christoph Bourauel
Journal:  Prog Orthod       Date:  2016-01-15       Impact factor: 2.750

Review 4.  Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

Authors:  Yousef Al-Thomali; Roshan-Noor Mohamed; Sakeenabi Basha
Journal:  J Clin Exp Dent       Date:  2017-01-01

5.  Impact of different rectangular wires on torsional expression of different sizes of buccal tube.

Authors:  Shabnam Ajami; Afshar-Rasti Boroujeni
Journal:  J Clin Exp Dent       Date:  2018-01-01

6.  Three-dimensional deformation of orthodontic brackets.

Authors:  Garrett W Melenka; David S Nobes; Paul W Major; Jason P Carey
Journal:  J Dent Biomech       Date:  2013-06-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.