Role of the lead structure in MRI-induced heating: In vitro measurements on 30 commercial pacemaker/defibrillator leads.

Eugenio Mattei1, Giovanni Calcagnini, Federica Censi, Michele Triventi, Pietro Bartolini.   

Abstract

MRI-induced heating on endocardial leads is a serious concern for the safety of patients with implantable pacemakers or cardioverter-defibrillator. The lead heating depends on many factors and its amount is largely variable. In this study, we investigated the role of those structural properties of the lead that are reported on the accompanying documents of the device: (1) fixation modality (active vs. passive); (2) number of electrodes (unipolar vs. bipolar); (3) length; (4) tip surface; and (5) tip and ring resistance. In vitro temperature and specific absorption rate measurements on 30 leads (27 pacemakers, three implantable cardioverter-defibrillator leads) exposed to the radiofrequency field typical of a 1.5 T MRI scanner are presented. The data show that each lead has its own attitude to radiofrequency-induced heating and that the information that is available in the accompanying documents of the pacemaker is not sufficient to explain such attitude. Even if combined with that of the implant geometry, this information is still not sufficient to estimate the amount of heating due to the exposure to the radiofrequency field during MRI examination.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21748795     DOI: 10.1002/mrm.23067

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  An optically coupled sensor for the measurement of currents induced by MRI gradient fields into endocardial leads.

Authors:  Eugenio Mattei; Federica Censi; Michele Triventi; Antonio Napolitano; Elisabetta Genovese; Vittorio Cannatà; Giovanni Calcagnini
Journal:  MAGMA       Date:  2014-10-11       Impact factor: 2.310

2.  A novel MR-compatible sensor to assess active medical device safety: stimulation monitoring, rectified radio frequency pulses, and gradient-induced voltage measurements.

Authors:  Thérèse Barbier; Sarra Aissani; Nicolas Weber; Cédric Pasquier; Jacques Felblinger
Journal:  MAGMA       Date:  2018-03-30       Impact factor: 2.310

3.  Patient Orientation Affects Lead-Tip Heating of Cardiac Active Implantable Medical Devices during MRI.

Authors:  Jessica A Martinez; Peter Serano; Daniel B Ennis
Journal:  Radiol Cardiothorac Imaging       Date:  2019-08-29

4.  MRI of Patients with Cardiac Implantable Electronic Devices.

Authors:  Jessica A Martinez; Daniel B Ennis
Journal:  Curr Cardiovasc Imaging Rep       Date:  2019-05-27

5.  A contribution to MRI safety testing related to gradient-induced heating of medical devices.

Authors:  Alessandro Arduino; Oriano Bottauscio; Mario Chiampi; Umberto Zanovello; Luca Zilberti
Journal:  Magn Reson Med       Date:  2022-03-28       Impact factor: 3.737

6.  2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients.

Authors:  Maully J Shah; Michael J Silka; Jennifer N Avari Silva; Seshadri Balaji; Cheyenne M Beach; Monica N Benjamin; Charles I Berul; Bryan Cannon; Frank Cecchin; Mitchell I Cohen; Aarti S Dalal; Brynn E Dechert; Anne Foster; Roman Gebauer; M Cecilia Gonzalez Corcia; Prince J Kannankeril; Peter P Karpawich; Jeffery J Kim; Mani Ram Krishna; Peter Kubuš; Martin J LaPage; Douglas Y Mah; Lindsey Malloy-Walton; Aya Miyazaki; Kara S Motonaga; Mary C Niu; Melissa Olen; Thomas Paul; Eric Rosenthal; Elizabeth V Saarel; Massimo Stefano Silvetti; Elizabeth A Stephenson; Reina B Tan; John Triedman; Nicholas H Von Bergen; Philip L Wackel
Journal:  Indian Pacing Electrophysiol J       Date:  2021-07-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.