Literature DB >> 21748728

Biomechanical properties of axially myopic cornea.

Cigdem Altan1, Berna Demirel, Engin Azman, Banu Satana, Ercüment Bozkurt, Ahmet Demirok, Omer Faruk Yilmaz.   

Abstract

PURPOSE: To investigate biomechanical parameters of the cornea measured with ocular response analyzer (ORA) in myopic eyes with high axial length and the relationship between these parameters and axial length (AL).
METHODS: A total of 165 eyes of 165 consecutive patients were included. Eyes with AL greater than 26 mm were named group 1 and eyes with AL shorter than 26 mm were named group 2. Axial length and keratometric values were measured by intraocular lens (IOL) Master optical biometry. Metrics of corneal biomechanical properties, including corneal hysteresis (CH) and corneal resistance factor (CRF), were measured with the ORA. The ORA also determined the values of intraocular pressure (IOPg) and corneal compensated IOP (IOPcc).
RESULTS: The mean age of total subjects was 43.0 ± 15.6 years. Eighty-three eyes were included in group 1; 82 eyes were included in group 2. The CH and CRF of group 1 were significantly lower than group 2. The IOPcc was significantly higher in group 1 than group 2. When group 1 and group 2 were combined for analysis, CH was negatively correlated with age. Both CH and CRF were significantly correlated with SE. However, CH and CRF were negatively correlated with AL. Also, there was significant correlation between AL and IOPcc (p<0.05).
CONCLUSIONS: Highly myopic eyes showed decreased CH and CRF. As the AL increased the IOPcc also increased and the CH decreased. We conclude that the biomechanical properties of the cornea change with elongation of the eye and this may have an impact on IOP measurement.

Entities:  

Mesh:

Year:  2012        PMID: 21748728     DOI: 10.5301/ejo.5000010

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  6 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Effect of outdoor activity on myopia onset and progression in school-aged children in northeast China: the Sujiatun Eye Care Study.

Authors:  Ju-Xiang Jin; Wen-Juan Hua; Xuan Jiang; Xiao-Yan Wu; Ji-Wen Yang; Guo-Peng Gao; Yun Fang; Chen-Lu Pei; Song Wang; Jie-Zheng Zhang; Li-Ming Tao; Fang-Biao Tao
Journal:  BMC Ophthalmol       Date:  2015-07-09       Impact factor: 2.209

3.  Assessment of corneal biomechanical properties and intraocular pressure in myopic spanish healthy population.

Authors:  María A Del Buey; Laura Lavilla; Francisco J Ascaso; Elena Lanchares; Valentín Huerva; José A Cristóbal
Journal:  J Ophthalmol       Date:  2014-02-25       Impact factor: 1.909

4.  Evaluation of corneal hysteresis after pars plana vitrectomy combined phacoemulsification and intraocular lens implantation.

Authors:  Manami Ohta; Makiko Wakuta; Ayano Sakuma; Mina Hasegawa; Waka Hamada; Fumiaki Higashijima; Takuya Yoshimoto; Tadahiko Ogata; Yuka Kobayashi; Kazuhiro Kimura
Journal:  Sci Rep       Date:  2022-08-26       Impact factor: 4.996

5.  Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis.

Authors:  Ihab Mohamed Osman; Hany Ahmed Helaly; Moones Abdalla; Mohsen Abou Shousha
Journal:  BMC Ophthalmol       Date:  2016-07-26       Impact factor: 2.209

6.  Corneal Biomechanics Determination in Healthy Myopic Subjects.

Authors:  Kunliang Qiu; Xuehui Lu; Riping Zhang; Geng Wang; Mingzhi Zhang
Journal:  J Ophthalmol       Date:  2016-07-21       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.