Literature DB >> 21744789

Signal enhancement for peptide analysis in liquid chromatography-electrospray ionization mass spectrometry with trifluoroacetic acid containing mobile phase by postcolumn electrophoretic mobility control.

Nan-Hsuan Wang1, Wan-Li Lee, Guor-Rong Her.   

Abstract

A strategy based on postcolumn electrophoretic mobility control (EMC) was developed to alleviate the adverse effect of trifluoroacetic acid (TFA) on the liquid chromatography-mass spectrometry (LC-MS) analysis of peptides. The device created to achieve this goal consisted of a poly(dimethylsiloxane) (PDMS)-based junction reservoir, a short connecting capillary, and an electrospray ionization (ESI) sprayer connected to the outlet of the high-performance liquid chromatography (HPLC) column. By apply different voltages to the junction reservoir and the ESI emitter, an electric field was created across the connecting capillary. Due to the electric field, positively charged peptides migrated toward the ESI sprayer, whereas TFA anions remained in the junction reservoir and were removed from the ionization process. Because TFA did not enter the ESI source, ion suppression from TFA was alleviated. Operation of the postcolumn device was optimized using a peptide standard mixture. Under optimized conditions, signals for the peptides were enhanced 9-35-fold without a compromise in separation efficiency. The optimized conditions were also applied to the LC-MS analysis of a tryptic digest of bovine serum albumin.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21744789     DOI: 10.1021/ac2003714

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Signal and Charge Enhancement for Protein Analysis by Liquid Chromatography-Mass Spectrometry with Desorption Electrospray Ionization.

Authors:  Yan Liu; Zhixin Miao; Rajeswari Lakshmanan; Rachel R Ogorzalek Loo; Joseph A Loo; Hao Chen
Journal:  Int J Mass Spectrom       Date:  2012-07-01       Impact factor: 1.986

2.  Membrane-based continuous remover of trifluoroacetic acid in mobile phase for LC-ESI-MS analysis of small molecules and proteins.

Authors:  Zhigui Zhou; Jialing Zhang; Jiawei Xing; Yu Bai; Yiping Liao; Huwei Liu
Journal:  J Am Soc Mass Spectrom       Date:  2012-04-20       Impact factor: 3.109

3.  Enhancing Sensitivity of Liquid Chromatography-Mass Spectrometry of Peptides and Proteins Using Supercharging Agents.

Authors:  Michael Nshanian; Rajeswari Lakshmanan; Hao Chen; Rachel R Ogorzalek Loo; Joseph A Loo
Journal:  Int J Mass Spectrom       Date:  2017-12-24       Impact factor: 1.986

4.  Microfluidic ion stripper for removal of trifluoroacetic acid from mobile phases used in HILIC-MS of intact proteins.

Authors:  Sam Wouters; Sebastiaan Eeltink; Rob Haselberg; Govert W Somsen; Andrea F G Gargano
Journal:  Anal Bioanal Chem       Date:  2021-05-28       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.