Literature DB >> 21740835

Hemodynamic parameters obtained by transthoracic echocardiography and right heart catheterization: a comparative study in patients with pulmonary hypertension.

Zhuang Tian1, Yong-Tai Liu, Quan Fang, Chao Ni, Tai-Bo Chen, Li-Gang Fang, Peng Gao, Xiu-Chun Jiang, Meng-Tao Li, Xiao-Feng Zeng.   

Abstract

BACKGROUND: Hemodynamic evaluation is crucial for the management of patients with pulmonary hypertention. Clinicians often prefer a rapid and non-invasive method. This study aimed to examine the feasibility of transthoracic echocardiography for the measurements of hemodynamic parameters in patients with pulmonary hypertension.
METHODS: A prospective single-center study was conducted among 42 patients with pulmonary hypertension caused by different diseases. Transthoracic echocardiography and right-heart catheterization were performed within 24 hours. Pulmonary artery systolic, diastolic and mean pressure (PASP, PADP and PAMP), cardiac output (CO), and pulmonary capillary wedge pressure (PCWP) were measured by both methods. A linear correlation and a Bland-Altman analysis were performed to compare the two groups of hemodynamic parameters.
RESULTS: A good correlation was found between invasive and non-invasive measurements for PASP (r = 0.96), PADP (r = 0.85), PAMP (r = 0.88), CO (r = 0.82), and PCWP (r = 0.81). Further agreement analysis done by the Bland-Altman method showed that bias and a 95% confidence interval for PASP, PADP, and CO were clinically acceptable while great discrepancies existed for PAMP and PCWP.
CONCLUSIONS: The non-invasive measurements by PASP, PADP, and CO in patients with pulmonary hypertension correlate well with the invasive determinations. Transthoracic echocardiography (TTE) was inappropriate for estimating PCWP and PAMP.

Entities:  

Mesh:

Year:  2011        PMID: 21740835

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  5 in total

1.  ECG-gated computed tomography to assess pulmonary capillary wedge pressure in pulmonary hypertension.

Authors:  Nancy Sauvage; Emilie Reymond; Adrien Jankowski; Marion Prieur; Christophe Pison; Hélène Bouvaist; Gilbert R Ferretti
Journal:  Eur Radiol       Date:  2013-06-09       Impact factor: 5.315

Review 2.  Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable.

Authors:  Mik Wetterslev; Hasse Møller-Sørensen; Rasmus Rothmann Johansen; Anders Perner
Journal:  Intensive Care Med       Date:  2016-03-01       Impact factor: 17.440

3.  Left atrial acceleration factor as a magnetic resonance 4D flow measure of mean pulmonary artery wedge pressure in pulmonary hypertension.

Authors:  Gert Reiter; Gabor Kovacs; Clemens Reiter; Albrecht Schmidt; Michael Fuchsjäger; Horst Olschewski; Ursula Reiter
Journal:  Front Cardiovasc Med       Date:  2022-08-03

4.  Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study.

Authors:  Nagehan Aslan; Dincer Yildizdas; Ozden Ozgur Horoz; Yasemin Coban; Fadli Demir; Sevcan Erdem; Yasar Sertdemir
Journal:  Ital J Pediatr       Date:  2020-04-16       Impact factor: 2.638

5.  Cardiac output measured by transthoracic echocardiography and Swan-Ganz catheter. A comparative study in mechanically ventilated patients with high positive end-expiratory pressure.

Authors:  José Gorrasi; Arturo Pazos; Lucia Florio; Carlos Américo; Natalia Lluberas; Gabriel Parma; Ricardo Lluberas
Journal:  Rev Bras Ter Intensiva       Date:  2019 Oct-Dec
  5 in total