Literature DB >> 21739116

Cross-linked ultra-high-molecular weight polyethylene liner and ceramic femoral head in total hip arthroplasty: a prospective study at 5 years follow-up.

Iñigo Orradre Burusco1, Raquel Romero, Miriam Brun, Jose Javier López Blasco.   

Abstract

BACKGROUND: Recent data indicate that enhanced wear resistance can be obtained with new cross-linked ultra-high-molecular weight polyethylene (CL-UHMWPE) liners, in comparison with previous-generation liners. The current prospective, cohort study was undertaken to analyse whether the use of a new CL-UHMWPE (Rexpol) results in a lower wear rate than ultra-high-molecular weight polyethylene (UHMWPE) in a group of similar patients undergoing total hip arthroplasty (THA). This study provides the first clinical data with this particular CL-UHMWPE.
METHODS: Between January 2001 and December 2001, patients underwent THA with biconical threaded cups and ceramic femoral heads using either a CL-UHMWPE liner (n = 50) or a regular UHMWPE liner (n = 57). At the time of the final 5-year evaluation, there were 48 patients available in the CL-UHMWPE and 54 patients available in the UHMWPE group.
RESULTS: After a mean 5.6 years follow-up, there were no significant differences between the groups in Harris Hip Score outcomes. However, there was a 69.1% decrease in wear at 5 years for the CL-UHMWPE group in comparison with the UHMWPE group (p < 0.01).
CONCLUSION: The use of CL-UHMWPE significantly reduced the risk of polyethylene wear in patients undergoing THA with biconical threaded cups and ceramic femoral heads. Further follow-up is needed to determine how this will influence long-term outcomes.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21739116     DOI: 10.1007/s00402-011-1340-3

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

2.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

3.  Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial.

Authors:  Justin van Loon; Daniël Hoornenborg; Inger Sierevelt; Kim Tm Opdam; Gino Mmj Kerkhoffs; Daniël Haverkamp
Journal:  World J Orthop       Date:  2020-10-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.