Inter-fraction prostate motion during intensity-modulated radiotherapy for prostate cancer.

T R Siow1, C L Ngoi, W K Tan.   

Abstract

INTRODUCTION: This study aimed to analyse the inter-fraction prostate motion and setup error during intensity-modulated radiotherapy for prostate cancer at the National Cancer Centre Singapore.
METHODS: Gold seeds were implanted as fiducial markers. Daily portal films were taken and displacements of the gold seeds from the isocentre in each axis were recorded. Random and systematic errors were used to derive a margin recipe for each axis based on the van Herk formula.
RESULTS: 1,077 fractions from 36 patients were analysed. 89.8 percent, 85.2 percent and 83.6 percent of the setup errors were within +/- 2 mm for the right-left (RL), superior-inferior (SI) and anterior-posterior (AP) axes, respectively. The population systematic errors were 0.71 mm, 0.84 mm and 0.87 mm; the population random errors were 1.32 mm, 1.59 mm and 1.70 mm; the overall population mean setup errors were -0.14 (range -2.27 to 1.15) mm, 0.11 (range -2.32 to 1.69) mm and 0.08 (range -1.33 to 1.46) mm; and the van Herk margin recipes were 2.69 mm, 3.22 mm and 3.37 mm for the RL, SI and AP axes, respectively.
CONCLUSION: The setup errors and inter-fraction prostate movements were small. Gold seed implantation is a feasible and easy method of verifying the prostate position.

Entities:  

Mesh:

Year:  2011        PMID: 21731991

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  4 in total

Review 1.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

2.  A comparison of interfraction setup error, patient comfort, and therapist acceptance for 2 different prostate radiation therapy immobilization devices.

Authors:  Eric Pei Ping Pang; Kellie Knight; Marilyn Baird; Joshua Ming Quan Loh; Adelene Hwee San Boo; Jeffrey Kit Loong Tuan
Journal:  Adv Radiat Oncol       Date:  2017-02-16

3.  Reduction of intra-fraction prostate motion - Determining optimal bladder volume and filling for prostate radiotherapy using daily 4D TPUS and CBCT.

Authors:  Eric Pei Ping Pang; Kellie Knight; Ashik Hussain; Qiao Fan; Marilyn Baird; Sheena Xue Fei Tan; Wing-Ho Mui; Ronnie Wing-Kin Leung; Irene Kai Ling Seah; Zubin Master; Jeffrey Kit Loong Tuan
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2018-02-15

4.  Comparison of prostate verification with implanted gold markers in tissue surrounding the prostate and pelvic bony anatomy for external beam radiation therapy following low-dose-rate brachytherapy: a prospective clinical trial.

Authors:  Tomoya Kaneda; Toshio Ohashi; Takashi Hanada; Koji Takenaka; Shuichi Nishimura; Masanori Sakayori; Shinya Sutani; Tetsuo Momma; Naoyuki Shigematsu
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.