In vitro evaluation of the impact of ultrasound scanner settings and contrast bolus volume on time-intensity curves.

Thomas P Gauthier1, Mohamed Chebil, Pierre Peronneau, Nathalie Lassau.   

Abstract

The objective of this study was to assess in vitro the impact of ultrasound scanner settings and contrast bolus volume on time-intensity curves formed from dynamic contrast-enhanced ultrasound image loops. An indicator-dilution experiment was developed with an in vitro flow phantom setup used with SonoVue contrast agent (Bracco SpA, Milan, Italy). Imaging was performed with a Philips iU22 scanner and two transducers (L9-3 linear and C5-1 curvilinear). The following ultrasound scanner settings were investigated, along with contrast bolus volume: contrast-specific nonlinear pulse sequence, gain, mechanical index, focal zone depth, acoustic pulse center frequency and bandwidth. Four parameters (rise time, mean transit time, peak intensity, and area under the curve) were derived from time-intensity curves which were obtained after pixel by pixel linearization of log-compressed data (also referred to as video data) included in a region of interest. Rise time was found to be the parameter least impacted by changes to ultrasound scanner settings and contrast bolus volume; the associated coefficient of variation varied between 0.7% and 6.9% while it varied between 0.8% and 19%, 12% and 71%, and 9.2% and 66%, for mean transit time, peak intensity, and area under the curve, respectively. The present study assessed the impact of ultrasound scanner settings and contrast bolus volume on time-intensity curve analysis. One should be aware of these issues to standardize their technique in each specific organ of interest and to achieve accurate, sensitive, and reproducible data using dynamic contrast-enhanced ultrasound. One way to mitigate the impact of ultrasound scanner settings in longitudinal, multi-center quantitative dynamic contrast-enhanced ultrasound studies may be to prohibit any adjustments to those settings throughout a given study. Further clinical studies are warranted to confirm the reproducibility and diagnostic or prognostic value of time-intensity curve parameters measurements in a particular clinical scenario of interest, for example that of cancer patients undergoing vascular targeting therapies.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21722933     DOI: 10.1016/j.ultras.2011.06.003

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

1.  Interobserver Variation of the Bolus-and-Burst Method for Pancreatic Perfusion with Dynamic - Contrast-Enhanced Ultrasound.

Authors:  Marcus Stangeland; Trond Engjom; Martin Mezl; Radovan Jirik; Odd Helge Gilja; Georg Dimcevski; Kim Nylund
Journal:  Ultrasound Int Open       Date:  2017-09-12

Review 2.  Contrast-enhanced ultrasound of the pediatric brain.

Authors:  Misun Hwang; Carol E Barnewolt; Jörg Jüngert; Francesco Prada; Anush Sridharan; Ryne A Didier
Journal:  Pediatr Radiol       Date:  2021-02-18

3.  Early Prediction of Response to Neoadjuvant Chemotherapy Using Dynamic Contrast-Enhanced MRI and Ultrasound in Breast Cancer.

Authors:  Yunju Kim; Sung Hun Kim; Byung Joo Song; Bong Joo Kang; Kwang-Il Yim; Ahwon Lee; Yoonho Nam
Journal:  Korean J Radiol       Date:  2018-06-14       Impact factor: 3.500

4.  Contrast-Enhanced Ultrasonography-Based Hepatic Perfusion for Early Prediction of Prognosis in Acute Liver Failure.

Authors:  Hidekatsu Kuroda; Tamami Abe; Yudai Fujiwara; Tomoaki Nagasawa; Yuji Suzuki; Keisuke Kakisaka; Yasuhiro Takikawa
Journal:  Hepatology       Date:  2021-05-24       Impact factor: 17.425

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.