Determination of typical patterns from strongly varying signals.

A Bender1, G Bergmann.   

Abstract

Forces measured in human joints vary considerably when an activity such as walking is carried out by different subjects or when it is repeated. 'Typical' standardised force-time patterns are needed to test and improve joint implants. Mechanically most important for their endurance are the magnitudes and times of force maxima and minima. They should equal the arithmetic means from the single measurements. Similar problems exist when evaluating other strongly varying signals, as in gait analysis. The new method to calculate typical signals (TSs) enhances existing dynamic time warping (DTW) procedures. It allows us to combine any number of signals. The sequence of input signals--used for calculating the TS--has only a minor influence. The accuracy of the method was tested numerically on signals for which the typical patterns could be defined exactly, and also on real joint forces that varied to different extents.

Entities:  

Mesh:

Year:  2011        PMID: 21722048     DOI: 10.1080/10255842.2011.560841

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  16 in total

1.  Analysis of hip joint loading during walking with different shoe types using instrumented total hip prostheses.

Authors:  Y Palmowski; S Popović; D Kosack; P Damm
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

2.  Velocity of lordosis angle during spinal flexion and extension.

Authors:  Tobias Consmüller; Antonius Rohlmann; Daniel Weinland; Claudia Druschel; Georg N Duda; William R Taylor
Journal:  PLoS One       Date:  2012-11-16       Impact factor: 3.240

3.  In vivo hip joint loading during post-operative physiotherapeutic exercises.

Authors:  Verena Schwachmeyer; Philipp Damm; Alwina Bender; Jörn Dymke; Friedmar Graichen; Georg Bergmann
Journal:  PLoS One       Date:  2013-10-29       Impact factor: 3.240

4.  Knee adduction moment and medial contact force--facts about their correlation during gait.

Authors:  Ines Kutzner; Adam Trepczynski; Markus O Heller; Georg Bergmann
Journal:  PLoS One       Date:  2013-12-02       Impact factor: 3.240

5.  Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.

Authors:  Philipp Damm; Alwina Bender; Georg Bergmann
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

6.  In vivo measured joint friction in hip implants during walking after a short rest.

Authors:  Philipp Damm; Alwina Bender; Georg Duda; Georg Bergmann
Journal:  PLoS One       Date:  2017-03-28       Impact factor: 3.240

7.  Standardized loads acting in knee implants.

Authors:  Georg Bergmann; Alwina Bender; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Adam Trepczynski; Markus O Heller; Ines Kutzner
Journal:  PLoS One       Date:  2014-01-23       Impact factor: 3.240

8.  Friction in total hip joint prosthesis measured in vivo during walking.

Authors:  Philipp Damm; Joern Dymke; Robert Ackermann; Alwina Bender; Friedmar Graichen; Andreas Halder; Alexander Beier; Georg Bergmann
Journal:  PLoS One       Date:  2013-11-08       Impact factor: 3.240

9.  Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions?

Authors:  Tim A Weber; Sebastian Dendorfer; Joachim Grifka; Gijsbertus J Verkerke; Tobias Renkawitz
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

10.  Standardized Loads Acting in Hip Implants.

Authors:  Georg Bergmann; Alwina Bender; Jörn Dymke; Georg Duda; Philipp Damm
Journal:  PLoS One       Date:  2016-05-19       Impact factor: 3.240