Literature DB >> 21716097

Comparison of dynamic contour tonometry and Goldmann applanation tonometry in keratoconus.

Jan Darius Unterlauft1, Nina Schädle, Karsten Kasper, Thomas Klink, Gerd Geerling.   

Abstract

PURPOSE: We performed a comparative study using Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) to measure intraocular pressure (IOP) in eyes with keratoconus.
METHODS: IOP was measured in 114 eyes of 75 patients with keratoconus (51 men and 24 women; mean age, 36.1 ± 11.2 years) using GAT and DCT in randomized order. Central corneal thickness (CCT), minimal corneal thickness (MCT), and corneal topography were recorded using the Pentacam. Four groups according to Amsler's keratoconus classification were composed and analyzed for significant differences of CCT, MCT, GAT, and DCT results.
RESULTS: Mean CCT in the 114 keratoconus eyes was 481.1 ± 46.2 μm (range, 334-601 μm). Mean MCT was 453.3 ± 56.3 μm (range, 239-573 μm). Mean IOP measured using GAT was 13.1 ± 2.9 mm Hg, whereas mean IOP measured using DCT was 14.8 ± 2.6 mm Hg. Neither the results for GAT nor those for DCT showed a significant correlation with CCT (Pearson correlation: P < 0.05). Multifactorial analysis revealed that CCT and MCT, but not GAT and DCT, results were significantly different in corneas of varying curvatures.
CONCLUSIONS: This study shows that DCT measures IOP higher than GAT in eyes with keratoconus. In keratoconus, both methods seem to be independent of CCT and therefore are equally, but not interchangeably, applicable when monitoring IOP. Further analysis revealed that CCT and MCT are significantly different in corneas of varying Amsler grade.

Entities:  

Mesh:

Year:  2011        PMID: 21716097     DOI: 10.1097/ICO.0b013e31820cd3d6

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

2.  Which tonometry in eyes with keratoconus?

Authors:  H Altinkaynak; C Kocasarac; H Dundar; N Sayin; N Kara; E Bozkurt; N Duru
Journal:  Eye (Lond)       Date:  2015-12-04       Impact factor: 3.775

3.  Twenty-four hours intraocular pressure in keratoconic eyes assessed by applanation tonometry and Tono-Pen AVIA.

Authors:  Rafael Vidal Merola; Sebastião Cronemberger; Artur William Veloso; Alberto Diniz-Filho
Journal:  Int J Ophthalmol       Date:  2022-01-18       Impact factor: 1.779

4.  Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus.

Authors:  Fatih Özcura; Nilgün Yıldırım; Emre Tambova; Afsun Şahin
Journal:  J Optom       Date:  2016-07-09

5.  Comparison of IOP Measurement by Goldmann Applanation Tonometer, ICare Rebound Tonometer, and Tono-Pen in Keratoconus Patients after MyoRing Implantation.

Authors:  Mahmoud Rateb; Mahmoud Abdel-Radi; Zeiad Eldaly; Mohamed Nagy Elmohamady; Asaad Noor El Din
Journal:  J Ophthalmol       Date:  2019-05-09       Impact factor: 1.909

  5 in total