BACKGROUND: There is no simple and practical way to monitor sleep patterns in patients in acute care units. We designed this study to assess sleep patterns, energy expenditure and circadian rhythms of patients' skin temperature in the coronary care unit (CCU) utilizing a new portable device. MATERIAL/Entities:
Mesh:
Year: 2011 PMID: 21709634 PMCID: PMC3539555 DOI: 10.12659/msm.881851
Source DB: PubMed Journal: Med Sci Monit ISSN: 1234-1010
Demographics and sleep characteristics of patients admitted to the CCU.
| Variable (n=46) | Mean ± SD |
|---|---|
| Male | 39 (85%) |
| Smoker | 14 (30%) |
| Number of patients staying only in the CCU | 18 (39%) |
| Number of patients staying in both the CCU & the ward | 28 (61%) |
| Age (years) | 58.7±8.6 |
| BMI (Kg/m2) | 26.7±5.4 |
| TST (hr) | 6.9±2.3 |
| Nighttime sleep duration (hr) | 5.8±2.0 |
| Nighttime sleep sessions | 2.3±0.6 |
| Nighttime sleep duration (hr)/session | 2.7±1.2 |
| NAP duration (hr) | 1.2±1 |
| Number of NAP sessions | 1.6±1 |
| NAP duration (hr)/session | 0.8±0.5 |
| Heat flux | 62.2±13 |
| Skin temperature (°C) | 32.7±0.6 |
| Near body temperature (°C) | 32.7±0.6 |
| Energy expenditure (kcal/min) | 1.2±0.2 |
| METs | 1±0.1 |
METs – metabolic equivalents of task; CCU – coronary care unit.
Comparison between sleep characteristics and energy expenditure in the CCU and the wards.
| Variable | CCU n=28 | Ward n=28 | p value |
|---|---|---|---|
| TST (hr) | 6.66±2.43 | 7.49±2.42 | NS |
| Nighttime sleep duration (hr) | 5.64±2.21 | 6.23±2.03 | NS |
| Night sleep sessions | 2.47±0.51 | 2.13±0.81 | 0.056 |
| Night sleep (hr)/session | 2.40±1.11 | 3.53±2.30 | 0.015 |
| NAP duration (hr) | 1.26±1.06 | 1.26±1.09 | NS |
| Nap sessions | 1.54±1.04 | 1.40±1.14 | NS |
| NAP duration (hr)/session | 0.76±0.48 | 0.67±0.50 | NS |
| Total sleep sessions | 7.39±3.48 | 8.79±5.43 | NS |
| Night sleep + NAP duration (hr)/session | 1.71±0.66 | 2.34±1.11 | 0.004 |
| Heat flux | 61.93±13.21 | 63.22±13.8 | NS |
| Skin temperature (°C) | 32.76±0.61 | 33.04±0.47 | 0.011 |
| Near body temperature (°C) | 32.73±0.63 | 33.01±0.47 | 0.013 |
| Energy expenditure (kcal/min) | 1.19±0.18 | 1.24±0.19 | 0.000 |
| METs | 1.00±0.13 | 1.05±0.15 | 0.000 |
TST – total sleep time; METs – metabolic equivalents of task.
Cosinor Model results for skin temperature and energy expenditure in the CCU and the wards.
| CCU | Ward | P-value | |
|---|---|---|---|
| Skin temperature (°C) | |||
| MESOR | 32.79±0.79 | 33.06±0.59 | 0.104 |
| Amplitude | 0.66±0.3 | 0.62±0.33 | 0.715 |
| Acrophase (24 hr) | 13.31±9.53 | 10.58±9.58 | 0.437 |
| MESOR* | 1.22±0.19 | 1.28±0.2 | 0.007 |
| Amplitude* | 0.05±0.03 | 0.1±0.08 | 0.005 |
| Acrophase (24 hr) | 11.85±7.24 | 9.24±7.46 | 0.335 |
Figure 1Distribution of sleep over the first 24 hr in the CCU (A) and the general ward (B).
Noise levels in the CCU and the wards.
| Attributes | Maximum (dB) | Average (dB) | Minimum (dB) |
|---|---|---|---|
| CCU | 85 | 70 | 50 |
| Male ward | 88 | 65 | 40 |
| Female ward | 85 | 55 | 25 |
CCU – coronary care unit.