Experimental results from a prototype slit-slat collimator with mixed multiplexed and non-multiplexed data.

Shelan Mahmood1, Kjell Erlandsson, Ian Cullum, Brian Hutton.   

Abstract

We have previously shown with simulations that a gain in signal-to-noise ratio (SNR) can be obtained by using mixed multiplexed (MX) and non-MX data in a slit-slat SPECT system as compared to using non-MX data only. We have now developed a prototype slit-slat collimator for a conventional gamma camera in order to validate these simulation results. The prototype collimator consists of seven slits and multiple parallel slats. Image reconstruction is performed using a modified OSEM algorithm, which takes into account geometric sensitivity variations and attenuation, but not scatter or resolution effects. Here, we first describe the calibration of the system and then we present the experimental validation with phantom experiments. SPECT acquisitions using different geometric and anthropomorphic phantoms were performed with and without multiplexing. The results show that reconstruction of the MX projections with the non-MX-projections eliminates artefacts caused by multiplexing. SNR gains obtained using the mixed MX and non-MX configurations were in the range of 26% to 51% for different phantoms. The results were in agreement with our previously published simulation work, proving that combining MX and non-MX data can result in artefact-free reconstructed images with improved SNR.

Mesh:

Year:  2011        PMID: 21709344     DOI: 10.1088/0031-9155/56/14/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A SPECT imager with synthetic collimation.

Authors:  Ronan J Havelin; Brian W Miller; Harrison H Barrett; Lars R Furenlid; J M Murphy; Mark J Foley
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-08-25

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Design and performance of a small-animal imaging system using synthetic collimation.

Authors:  R J Havelin; B W Miller; H H Barrett; L R Furenlid; J M Murphy; R M Dwyer; M J Foley
Journal:  Phys Med Biol       Date:  2013-04-26       Impact factor: 3.609

4.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

5.  Cerebral SPECT imaging with different acquisition schemes using varying levels of multiplexing versus sensitivity in an adaptive multi-pinhole brain-dedicated scanner.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Micaehla May; R Garrett Richards; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  Biomed Phys Eng Express       Date:  2021-09-22