Literature DB >> 21703907

Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study.

F Karaca1, B Aksakal, M Kom.   

Abstract

Orthopaedic drilling operations without optimum operating parameters by surgeons may cause bone defects such as bone fracture, cracks, osteolysis and tissue loss around the drilling zone. For the sake of optimum drilling parameters, an in vitro study was performed by considering the bone mineral density, bone sex, drill tip angle, drill speed, drill force and feed-rate. The specimens were taken from the drilled sites of fresh male and female calf tibias. The temperature changes at the drill site were investigated throughout the statistical and histopathological analysis. It was observed that the temperature increased with an increasing drill speed and decreased with high feed-rates and applied drill forces. The drilling temperatures of the female bovine tibias were found to be higher than that of the male tibias and the drill speed was found to be a significant parameter on the maximum temperature. Moreover, the maximum temperature increased with an increasing drill tip angle and bone mineral density. Therefore the bone quality around the drill site was found to be worse than the bone samples exposed to low temperatures.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21703907     DOI: 10.1016/j.medengphy.2011.05.013

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  12 in total

1.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

2.  Optimization of multiple quality characteristics in bone drilling using grey relational analysis.

Authors:  Rupesh Kumar Pandey; Sudhansu Sekhar Panda
Journal:  J Orthop       Date:  2014-07-17

3.  Evaluation of the parameters affecting bone temperature during drilling using a three-dimensional dynamic elastoplastic finite element model.

Authors:  Yung-Chuan Chen; Yuan-Kun Tu; Jun-Yan Zhuang; Yi-Jung Tsai; Cheng-Yo Yen; Chih-Kun Hsiao
Journal:  Med Biol Eng Comput       Date:  2017-03-28       Impact factor: 2.602

Review 4.  Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review.

Authors:  Mohd Faizal Ali Akhbar; Akmal Wani Sulong
Journal:  Ann Biomed Eng       Date:  2020-08-28       Impact factor: 3.934

5.  Objective Evaluation of Motor Skills for Orthopedic Residents Using a Motion Tracking Drill System: Outcomes of an ABOS Approved Surgical Skills Training Program.

Authors:  Ashkan Pourkand; Christina Salas; Jasmin Regalado; Krishan Bhakta; Rachel Tufaro; Deana Mercer; David Grow
Journal:  Iowa Orthop J       Date:  2016

Review 6.  Drilling of bone: A comprehensive review.

Authors:  Rupesh Kumar Pandey; S S Panda
Journal:  J Clin Orthop Trauma       Date:  2013-01-18

Review 7.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

8.  Appraising efficiency of OpSite as coolant in drilling of bone.

Authors:  Mohammad Reza Effatparvar; Nima Jamshidi; Alireza Mosavar
Journal:  J Orthop Surg Res       Date:  2020-05-29       Impact factor: 2.359

9.  Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

Authors:  Luca Lamazza; Girolamo Garreffa; Domenica Laurito; Marco Lollobrigida; Luigi Palmieri; Alberto De Biase
Journal:  Biomed Res Int       Date:  2016-03-24       Impact factor: 3.411

10.  Do increased drilling speed and depth affect bone viability at implant site?

Authors:  Reza Tabrizi; Ali Dehghani Nazhvanai; Mohammad Mahdi Farahmand; Sara Yasour Pourali; Sepanta Hosseinpour
Journal:  Dent Res J (Isfahan)       Date:  2017 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.