Literature DB >> 28353132

Evaluation of the parameters affecting bone temperature during drilling using a three-dimensional dynamic elastoplastic finite element model.

Yung-Chuan Chen1, Yuan-Kun Tu2, Jun-Yan Zhuang1, Yi-Jung Tsai2, Cheng-Yo Yen2, Chih-Kun Hsiao3.   

Abstract

A three-dimensional dynamic elastoplastic finite element model was constructed and experimentally validated and was used to investigate the parameters which influence bone temperature during drilling, including the drill speed, feeding force, drill bit diameter, and bone density. Results showed the proposed three-dimensional dynamic elastoplastic finite element model can effectively simulate the temperature elevation during bone drilling. The bone temperature rise decreased with an increase in feeding force and drill speed, however, increased with the diameter of drill bit or bone density. The temperature distribution is significantly affected by the drilling duration; a lower drilling speed reduced the exposure duration, decreases the region of the thermally affected zone. The constructed model could be applied for analyzing the influence parameters during bone drilling to reduce the risk of thermal necrosis. It may provide important information for the design of drill bits and surgical drilling powers.

Entities:  

Keywords:  Bone temperature; Drilling parameters; Elastoplastic finite element model; Thermal necrosis

Mesh:

Year:  2017        PMID: 28353132     DOI: 10.1007/s11517-017-1644-8

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  24 in total

Review 1.  Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data.

Authors:  A Mellal; H W A Wiskott; J Botsis; S S Scherrer; U C Belser
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

2.  Keeping osteocytes alive: a comparison of drilling and hammering k-wires into bone.

Authors:  B B G M Franssen; P J van Diest; A H Schuurman; M Kon
Journal:  J Hand Surg Eur Vol       Date:  2008-06

3.  Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production.

Authors:  S Iyer; C Weiss; A Mehta
Journal:  Int J Prosthodont       Date:  1997 Sep-Oct       Impact factor: 1.681

4.  Effect of drill speed on bone temperature.

Authors:  M B Abouzgia; J M Symington
Journal:  Int J Oral Maxillofac Surg       Date:  1996-10       Impact factor: 2.789

5.  Variability and anisotropy of mechanical behavior of cortical bone in tension and compression.

Authors:  Simin Li; Emrah Demirci; Vadim V Silberschmidt
Journal:  J Mech Behav Biomed Mater       Date:  2013-03-14

6.  The thermal effects of skeletal fixation-pin insertion in bone.

Authors:  L S Matthews; C A Green; S A Goldstein
Journal:  J Bone Joint Surg Am       Date:  1984-09       Impact factor: 5.284

7.  Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit.

Authors:  A R Eriksson; T Albrektsson
Journal:  J Prosthet Dent       Date:  1983-07       Impact factor: 3.426

8.  The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber.

Authors:  R A Eriksson; T Albrektsson
Journal:  J Oral Maxillofac Surg       Date:  1984-11       Impact factor: 1.895

9.  [The factors affecting thermal necrosis secondary to the application of the Ilizarov transosseous wire].

Authors:  Muharrem Inan; Bülent Mizrak; Kadir Ertem; Ahmet Harma; Nurzat Elmali; Irfan Ayan
Journal:  Acta Orthop Traumatol Turc       Date:  2005       Impact factor: 1.511

10.  Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.

Authors:  Goran Augustin; Slavko Davila; Toma Udilljak; Tomislav Staroveski; Danko Brezak; Slaven Babic
Journal:  Int Orthop       Date:  2012-07       Impact factor: 3.075

View more
  3 in total

Review 1.  Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review.

Authors:  Mohd Faizal Ali Akhbar; Akmal Wani Sulong
Journal:  Ann Biomed Eng       Date:  2020-08-28       Impact factor: 3.934

2.  Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.

Authors:  Mohammad Javad Ein-Afshar; Mostafa Shahrezaee; Mohammad Hossein Shahrezaee; Seyed Reza Sharifzadeh
Journal:  Arch Bone Jt Surg       Date:  2020-09

Review 3.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.