Literature DB >> 21700253

Validation of minimal luminal area measured by intravascular ultrasound for assessment of functionally significant coronary stenosis comparison with myocardial perfusion imaging.

Jung-Min Ahn1, Soo-Jin Kang, Gary S Mintz, Jun-Hyok Oh, Won-Jang Kim, Jong-Young Lee, Duk-Woo Park, Seung-Whan Lee, Young-Hak Kim, Cheol Whan Lee, Seong-Wook Park, Dae Hyuk Moon, Seung-Jung Park.   

Abstract

OBJECTIVES: This study sought to evaluate the ability of minimal luminal area (MLA) measured by intravascular ultrasound (IVUS) to assess the functional significance of coronary artery disease.
BACKGROUND: The use of IVUS to determine the functional significance of coronary artery lesions remains a matter for debate.
METHODS: From our prospective IVUS imaging database, between July 2009 and April 2010, 170 coronary lesions in 150 patients who underwent stress myocardial single-photon emission computed tomography (SPECT) performed within 1 month of IVUS evaluation were identified and analyzed. MLA and other parameters were measured by IVUS and compared with the results of myocardial SPECT.
RESULTS: Overall, 45 lesions had positive SPECT, and 125 lesions had negative SPECT. The MLA of lesions with positive SPECT was smaller than the MLA of those with negative SPECT (1.7 ± 0.5 mm² vs. 2.3 ± 1.1 mm², p < 0.001). By logistic regression analysis, MLA (odds ratio: 3.1 by decrease of 1 mm², 95% confidence interval [CI]: 1.75 to 5.5, p < 0.01) was an independent predictor of the positive SPECT. Using receiver-operator characteristic curve analysis, the best cutoff value of MLA was ≤ 2.1 mm² with an 86.7% sensitivity, a 50.4% specificity, a 38.6% positive predictive value, and a 91.3% negative predictive value versus lesions with a positive SPECT (area under the curve: 0.690, 95% CI: 0.615 to 0.759, p < 0.01).
CONCLUSIONS: The best cutoff value of MLA measured by IVUS to predict myocardial ischemia was 2.1 mm². The IVUS-measured MLA appeared to play a limited role in detecting functionally significant lesions assessed by myocardial SPECT.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21700253     DOI: 10.1016/j.jcin.2011.02.013

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  6 in total

Review 1.  Impact of plaque characteristics on the degree of functional stenosis.

Authors:  Pedro de Araújo Gonçalves; Alexandre Hideo-Kajita; Hector Manuel Garcia-Garcia
Journal:  Cardiovasc Diagn Ther       Date:  2017-04

2.  Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model.

Authors:  Srikara Viswanath Peelukhana; Kranthi K Kolli; Massoud A Leesar; Mohamed A Effat; Tarek A Helmy; Imran Arif; Eric W Schneeberger; Paul Succop; Rupak K Banerjee
Journal:  Heart Vessels       Date:  2013-04-30       Impact factor: 2.037

3.  Impact of Intravascular Ultrasound in Clinical Practice.

Authors:  Andres Vasquez; Neville Mistry; Jasvindar Singh
Journal:  Interv Cardiol       Date:  2014-08

Review 4.  Optical coherence tomography: from research to practice.

Authors:  Juan Luis Gutiérrez-Chico; Eduardo Alegría-Barrero; Rodrigo Teijeiro-Mestre; Pak Hei Chan; Hiroto Tsujioka; Ranil de Silva; Nicola Viceconte; Alistair Lindsay; Tiffany Patterson; Nicolas Foin; Takashi Akasaka; Carlo di Mario
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-02-13       Impact factor: 6.875

Review 5.  Ischemia-based Coronary Revascularization: Beyond Anatomy and Fractional Flow Reserve.

Authors:  Hong Seok Lim; Kyoung Woo Seo; Myeong Ho Yoon; Hyoung Mo Yang; Seung Jea Tahk
Journal:  Korean Circ J       Date:  2017-11-06       Impact factor: 3.243

6.  Clinical Outcomes in Patients with Intermediate Coronary Stenoses: MINIATURE Investigators (Korea MultIceNter TrIal on Long-Term Clinical Outcome According to the Plaque Burden and Treatment Strategy in Lesions with MinimUm Lumen ARea lEss Than 4 mm(2) Using Intravascular Ultrasound).

Authors:  Young Joon Hong; Yun Ha Choi; Soo Young Park; Chang Wook Nam; Jang Hyun Cho; Won Yu Kang; Sang Rok Lee; Sung Yun Lee; Sang Wook Kim; Sang Yeob Lim; Kyung Ho Yun; Jung Sun Kim; Jin Won Kim; Woong Chol Kang; Ki Seok Kim; Jin Ho Choi; Joong Wha Chung; Soo Joong Kim; Youngkeun Ahn; Myung Ho Jeong
Journal:  Korean Circ J       Date:  2014-05-20       Impact factor: 3.243

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.