Literature DB >> 21699855

Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections.

Katherine Y Le1, Muhammad R Sohail, Paul A Friedman, Daniel Z Uslan, Stephen S Cha, David L Hayes, Walter R Wilson, James M Steckelberg, Larry M Baddour.   

Abstract

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are associated with increased mortality. However, detailed analyses of the impact of device removal on mortality have been limited.
OBJECTIVE: This study sought to evaluate the impact of timing device removal on mortality in patients with CIED infections.
METHODS: We retrospectively reviewed all cases of CIED infections seen at Mayo Clinic Rochester between 1991 and 2008. The impact of device removal on 30-day and 1-year mortality was evaluated using Cox proportional hazards models.
RESULTS: Of 416 patients with CIED infection, 23 (5.5%) died by 30 days and 61 (14.6%) died by 1 year. Forty-four (12.0%) developed complications related to device removal, and 3 (0.8%) died. Complete procedural success was achieved in 341 (81.9%) and clinical success in 391 (93.9%) cases. In multivariate analysis, antimicrobial therapy without device removal was associated with a 7-fold increase in 30-day mortality (hazard ratio [HR] 6.97, 95% confidence interval [CI] 1.36 to 35.60). Although device removal complications were associated with increased mortality at 30 days (HR 4.33, 95% CI 1.47 to 12.70) and at 1 year (HR 3.77, 95% CI 1.88 to 7.55), immediate device removal, when compared to delay in device removal in favor of initial conservative therapy with antimicrobials alone, and no device removal, was associated with a 3-fold decrease in 1-year mortality (HR 0.35, 95% CI 0.16 to 0.75).
CONCLUSION: Although device removal resulted in fatal complications in a few patients, the mortality associated with a delay in device removal was significantly higher. Therefore, early and complete device removal was associated with improved outcomes.
Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21699855     DOI: 10.1016/j.hrthm.2011.05.015

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  35 in total

Review 1.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

2.  Impact of antiplatelet therapy on clinical manifestations and outcomes of cardiovascular infections.

Authors:  Ammar Habib; Larry M Baddour; M Rizwan Sohail
Journal:  Curr Infect Dis Rep       Date:  2013-08       Impact factor: 3.725

3.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

4.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

5.  Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Farid; Saira Ajmal; Geoffrey B Johnson; Larry M Baddour; Panithaya Chareonthaitawee; Paul A Friedman; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-09-14       Impact factor: 5.952

6.  Differences in laser lead extraction of infected vs. non-infected leads.

Authors:  Simon Pecha; Liesa Castro; Julia Vogler; Matthias Linder; Nils Gosau; Stephan Willems; Hermann Reichenspurner; Samer Hakmi
Journal:  Heart Vessels       Date:  2018-04-05       Impact factor: 2.037

7.  Clinical presentation and outcomes of cardiovascular implantable electronic device infections in hemodialysis patients.

Authors:  LaTonya J Hickson; Janelle Y Gooden; Katherine Y Le; Larry M Baddour; Paul A Friedman; David L Hayes; Walter R Wilson; James M Steckelberg; M Rizwan Sohail
Journal:  Am J Kidney Dis       Date:  2014-01-03       Impact factor: 8.860

8.  Management of Cardiac Electronic Device Infections: Challenges and Outcomes.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Jens Cosedis Nielsen
Journal:  Arrhythm Electrophysiol Rev       Date:  2016

9.  Mid-axillary pacemaker re-implantation after contralateral pocket infection in an emaciated elderly case.

Authors:  Tetsuji Morishita; Yusuke Sato; Yoshitomo Fukuoka; Kentaro Ishida; Ryotaro Urabe; Ryohei Shigehara; Yoshiki Minegishi; Hiroyasu Uzui; Hiroshi Tada
Journal:  J Cardiol Cases       Date:  2018-06-09

10.  Snare sheath versus evolution sheath in transvenous lead extraction.

Authors:  Jihua Kong; Yilun Tian; Fei Guo; Feng Ze; Jiangbo Duan; Long Wang; Xuebin Li; Jihong Guo
Journal:  Int J Clin Exp Med       Date:  2015-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.