Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification.

Angela M Caliendo1, Alexander Valsamakis, James W Bremer, Andrea Ferreira-Gonzalez, Suzanne Granger, Linda Sabatini, Gregory J Tsongalis, Yun F Wayne Wang, Belinda Yen-Lieberman, Steve Young, Nell S Lurain.   

Abstract

The performance characteristics of four different assays for hepatitis B virus (HBV) quantification were assessed: the Abbott RealTime HBV IUO, the Roche Cobas AmpliPrep/Cobas TaqMan HBV test, the Roche Cobas TaqMan HBV test with HighPure system, and the Qiagen artus HBV TM ASR. Limit of detection (LOD), linear range, reproducibility, and agreement were determined using a serially diluted plasma sample from a single chronically infected subject. Each assay was tested by at least three laboratories. The LOD of the RealTime and two TaqMan assays was approximately 1.0 log(10) IU/ml; for artus HBV (which used the lowest volume of extracted DNA), it was approximately 1.5 log(10) IU/ml. The linear range spanned 1.0 to at least 7.0 log(10) IU/ml for all assays. Median values were consistently lowest for artus HBV and highest for Cobas AmpliPrep/Cobas TaqMan HBV. Assays incorporating automated nucleic acid extraction were the most reproducible; however, the overall variability was minor since the standard deviations for the means of all tested concentrations were ≤0.32 log(10) IU/ml for all assays. False-positive results were observed with all assays; the highest rates occurred with tests using manual nucleic acid extraction. The performance characteristics of these assays suggest that they are useful for management and therapeutic monitoring of chronic HBV infection.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21697326      PMCID: PMC3147738          DOI: 10.1128/JCM.00471-11

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Chronic hepatitis B.

Authors:  Anna S F Lok; Brian J McMahon
Journal:  Hepatology       Date:  2007-02       Impact factor: 17.425

Review 2.  EASL Clinical Practice Guidelines: management of chronic hepatitis B.

Authors: 
Journal:  J Hepatol       Date:  2008-10-29       Impact factor: 25.083

Review 3.  Hepatitis B virus infection.

Authors:  Jules L Dienstag
Journal:  N Engl J Med       Date:  2008-10-02       Impact factor: 91.245

4.  Evaluation of the COBAS AmpliPrep-total nucleic acid isolation-COBAS TaqMan hepatitis B virus (HBV) quantitative test and comparison to the VERSANT HBV DNA 3.0 assay.

Authors:  Christophe Ronsin; Anne Pillet; Corinne Bali; Gérard-Antoine Denoyel
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

5.  Performance of the Cobas AmpliPrep/Cobas TaqMan real-time PCR assay for hepatitis B virus DNA quantification.

Authors:  Stéphane Chevaliez; Magali Bouvier-Alias; Syria Laperche; Jean-Michel Pawlotsky
Journal:  J Clin Microbiol       Date:  2008-02-20       Impact factor: 5.948

6.  Evaluation of the Abbott RealTime HBV DNA assay and comparison to the Cobas AmpliPrep/Cobas TaqMan 48 assay in monitoring patients with chronic cases of hepatitis B.

Authors:  Marco Ciotti; Fabbio Marcuccilli; Tania Guenci; Maria Grazia Prignano; Carlo Federico Perno
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

7.  Hepatitis B virus DNA levels and outcomes in chronic hepatitis B.

Authors:  Chien-Jen Chen; Hwai-I Yang; Uchenna H Iloeje
Journal:  Hepatology       Date:  2009-05       Impact factor: 17.425

8.  The natural history of chronic hepatitis B virus infection.

Authors:  Brian J McMahon
Journal:  Hepatology       Date:  2009-05       Impact factor: 17.425

9.  Fully automated quantitation of hepatitis B virus (HBV) DNA in human plasma by the COBAS AmpliPrep/COBAS TaqMan system.

Authors:  S Hochberger; D Althof; R Gallegos de Schrott; N Nachbaur; H Röck; H Leying
Journal:  J Clin Virol       Date:  2006-02-07       Impact factor: 3.168

  9 in total
  17 in total

1.  Comparison of three Roche hepatitis B virus viral load assay formats.

Authors:  Michael T Pyne; Lauren Vest; Jennifer Clement; Jessica Lee; Jessica R Rosvall; Kevin Luk; Michael Rossi; Bryan Cobb; David R Hillyard
Journal:  J Clin Microbiol       Date:  2012-04-25       Impact factor: 5.948

2.  Detection of hepatitis B virus infection: A systematic review.

Authors:  Mallika Ghosh; Srijita Nandi; Shrinwanti Dutta; Malay Kumar Saha
Journal:  World J Hepatol       Date:  2015-10-18

3.  Enhancement of PCR Detection Limit by Single-Tube Restriction Endonuclease-PCR (RE-PCR).

Authors:  Sibnarayan Datta; Raghvendra Budhauliya; Soumya Chatterjee; Vijay Veer; Runu Chakravarty
Journal:  Mol Diagn Ther       Date:  2016-06       Impact factor: 4.074

Review 4.  Diagnosis of hepatitis B.

Authors:  Jeong Eun Song; Do Young Kim
Journal:  Ann Transl Med       Date:  2016-09

5.  Electrochemical Biosensor for Sensitive Detection of Hepatitis B in Human Plasma.

Authors:  Ana Cristina Honorato de Castro; Leandro Toshio Kochi; José Manuel Rodrigueiro Flauzino; Márcia Maria Costa Nunes Soares; Valéria Almeida Alves; Luís Antônio da Silva; João Marcos Madurro; Ana Graci Brito-Madurro
Journal:  Appl Biochem Biotechnol       Date:  2022-02-19       Impact factor: 2.926

6.  Development of sensitive and specific loop-mediated isothermal amplification combined with lateral flow device for the rapid detection of hepatitis B virus infection.

Authors:  Soumendra Nath Maity; Revathi Poonati; Rudrama Devi Punati; Pratyusha Mallepaddi; Yogyata Marothi; Prudhvi Chand Mallepaddi
Journal:  Braz J Microbiol       Date:  2022-02-17       Impact factor: 2.214

Review 7.  Update on hepatitis B and C virus diagnosis.

Authors:  Livia Melo Villar; Helena Medina Cruz; Jakeline Ribeiro Barbosa; Cristianne Sousa Bezerra; Moyra Machado Portilho; Letícia de Paula Scalioni
Journal:  World J Virol       Date:  2015-11-12

8.  Rapid detection of hepatitis B virus in blood plasma by a specific and sensitive loop-mediated isothermal amplification assay.

Authors:  Dougbeh-Chris Nyan; Laura E Ulitzky; Nicoleta Cehan; Phillip Williamson; Valerie Winkelman; Maria Rios; Deborah R Taylor
Journal:  Clin Infect Dis       Date:  2014-04-04       Impact factor: 9.079

9.  Introduction of an automated system for the diagnosis and quantification of hepatitis B and hepatitis C viruses.

Authors:  Mt Cabezas-Fernandez; Mi Cabeza-Barrera
Journal:  Open Virol J       Date:  2012-11-30

10.  A multiplex two-color real-time PCR method for quality-controlled molecular diagnostic testing of FFPE samples.

Authors:  Jiyoun Yeo; Erin L Crawford; Thomas M Blomquist; Lauren M Stanoszek; Rachel E Dannemiller; Jill Zyrek; Luis E De Las Casas; Sadik A Khuder; James C Willey
Journal:  PLoS One       Date:  2014-02-21       Impact factor: 3.240

View more