Literature DB >> 21693792

SPECT using asymmetric pinholes with truncated projections.

Jianyu Lin1, Steven R Meikle.   

Abstract

Tomographic systems employing truncated projections have been developed for parallel and fan beam collimation and for cone beam CT but the idea has not been extensively explored in pinhole single photon emission computed tomography (SPECT). In this paper, we explore the sampling requirements and system performance of SPECT systems with asymmetric pinhole collimators and truncated projections. We demonstrate that complete 3D sampling can be achieved by using multiple detectors with truncated asymmetric pinholes, offset axially from each other, and a spiral orbit. The use of truncated projections can be exploited in the design of pinhole SPECT systems by moving the pinholes closer to the subject, resulting in increased sensitivity and improved spatial resolution. Truncated and untruncated pinhole systems were evaluated using the contrast-to-noise ratio (CNR) calculated from the linearized local impulse response as a figure of merit. The CNR for the truncated pinhole system was up to 60% greater than that for the untruncated system at matched resolution for a source voxel near the centre of a uniform phantom and 30% greater at the edge. We conclude that an object can be reconstructed from asymmetric pinholes with truncated projections, which leads to potentially important design considerations and applications in single- and multi-pinhole SPECT.

Mesh:

Year:  2011        PMID: 21693792     DOI: 10.1088/0031-9155/56/13/023

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Quantification of Tomographic Incompleteness in Cone-Beam Reconstruction.

Authors:  Rolf Clackdoyle; Frédéric Noo
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-22

3.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.