Literature DB >> 21691599

Effects of occlusal inclination and loading on mandibular bone remodeling: a finite element study.

Chaiy Rungsiyakull1, Pimdeun Rungsiyakull, Qing Li, Wei Li, Michael Swain.   

Abstract

PURPOSE: To provide a preliminary understanding of the biomechanics with respect to the effect of cusp inclination and occlusal loading on the mandibular bone remodeling.
MATERIALS AND METHODS: Three different cusp inclinations (0, 10, and 30 degrees) of a ceramic crown and different occlusal loading locations (central fossa and 1- and 2-mm offsets horizontally) were taken into account to explore the stresses and strains transferred from the crown to the surrounding dental bone through the implant. A strain energy density obtained from two-dimensional plane-strain finite element analysis was used as the mechanical stimulus to drive cancellous and cortical bone remodeling in a buccolingual mandibular section.
RESULTS: Different ceramic cusp inclinations had a significant effect on bone remodeling responses in terms of the change in the average peri-implant bone density and overall stability. The remodeling rate was relatively high in the first few months of loading and gradually decreased until reaching its equilibrium. A larger cusp inclination and horizontal offset (eg, 30 degrees and 2-mm offset) led to a higher bone remodeling rate and greater interfacial stress.
CONCLUSIONS: The dental implant superstructure design (in terms of cusp inclination and loading location) determines the load transmission pattern and thus largely affects bone remodeling activities. Although the design with a lower cusp inclination recommended in previous studies may reduce damage and fracture failure, it could, to a certain extent, compromise bone engagement and long-term stability.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21691599

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

Review 1.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

2.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

3.  3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

Authors:  M DI Girolamo; L Baggi; P Pirelli; L Pappalardo; G Massei; F Iaculli; G Iezzi; A Piattelli; R Calcaterra
Journal:  Oral Implantol (Rome)       Date:  2017-11-30

4.  Finite Element Analysis of effect of cusp inclination and occlusal contacts in PFM and PEEK implant-supported crowns on resultant stresses.

Authors:  Githanjali Manchikalapudi; Sreeramulu Basapogu
Journal:  Med J Armed Forces India       Date:  2021-01-16

5.  Stress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis.

Authors:  Shima Aalaei; Zahra Rajabi Naraki; Fatemeh Nematollahi; Elaheh Beyabanaki; Afsaneh Shahrokhi Rad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

6.  An ectodermal dysplasia patient treated with a small diameter implant supporting a single crown.

Authors:  Andrea Mascolo; Elio Boschetti; Dennis Flanagan
Journal:  Clin Cosmet Investig Dent       Date:  2018-08-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.