Literature DB >> 21691594

Platform switching: biomechanical evaluation using three-dimensional finite element analysis.

Lucas Fernando Tabata1, Eduardo Passos Rocha, Valentim Adelino Ricardo Barão, Wirley Goncalves Assunção.   

Abstract

PURPOSE: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept.
MATERIALS AND METHODS: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software.
RESULTS: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue.
CONCLUSION: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system.

Entities:  

Mesh:

Year:  2011        PMID: 21691594

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  14 in total

1.  Platform switching vs standard implants in partially edentulous patients using the Dental Tech Implant System: clinical and radiological results from a prospective multicenter study.

Authors:  Massimo Del Fabbro; Carlo Bianchessi; Riccardo Del Lupo; Luca Landi; Silvio Taschieri; Stefano Corbella
Journal:  Clin Oral Investig       Date:  2015-03-31       Impact factor: 3.573

2.  Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads.

Authors:  Ángel Álvarez-Arenal; Luis Segura-Mori; Ignacio Gonzalez-Gonzalez; Hector DeLlanos-Lanchares; Fernando Sanchez-Lasheras; Joseba Ellacuria-Echevarria
Journal:  Odontology       Date:  2016-03-04       Impact factor: 2.634

3.  A Finite Element Stress Analysis of a Concical Triangular Connection in Implants: A New Proposal.

Authors:  Romy Angeles Maslucan; John Alexis Dominguez
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

4.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

5.  Biomechanical effects of platform switching in two different implant systems: a three-dimensional finite element analysis.

Authors:  Mahasti Sahabi; Mehdi Adibrad; Fatemeh Sadat Mirhashemi; Sareh Habibzadeh
Journal:  J Dent (Tehran)       Date:  2013-05-31

6.  Stability of external and internal implant connections after a fatigue test.

Authors:  Paulo Cesar Pinheiro Feitosa; Ana Paula Barbosa de Lima; Laís Regiane Silva-Concílio; William Cunha Brandt; Ana Christina Claro Neves
Journal:  Eur J Dent       Date:  2013-07

7.  The effect of platform switching on the levels of metal ion release from different implant-abutment couples.

Authors:  Ghada O Alrabeah; Jonathan C Knowles; Haralampos Petridis
Journal:  Int J Oral Sci       Date:  2016-06-30       Impact factor: 6.344

8.  Effect of platform switching on the peri-implant bone: A finite element study.

Authors:  Kheira Bouazza-Juanes; Amparo Martínez-González; Germán Peiró; Juan-José Ródenas; María-Victoria López-Mollá
Journal:  J Clin Exp Dent       Date:  2015-10-01

9.  A staged approach of implant placement in immediate extraction sockets for preservation of peri-implant soft and hard tissue.

Authors:  Dileep Nag Vinnakota; Sreenivasa Rao Akula; V Vamsi Krishna Reddy; V Vijay Sankar
Journal:  J Indian Soc Periodontol       Date:  2014-03

10.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728