Literature DB >> 21686562

Internet diagnosis of digitalis toxicity.

Marco Antonio Mercader1, Yousef Bader.   

Abstract

A 65-year-old male with an ischaemic cardiomyopathy and an implantable cardioverter defibrillator got a shock at home. A web-based monitoring system was used to check his device, and the interrogation showed that he had had several episodes of ventricular fibrillation and new onset of complete heart block that required back-up pacing by his defibrillator. The combination of enhanced automaticity (frequent premature ventricular complexes and ventricular arrhythmias) and impaired conduction (heart block) are the hallmarks of digitalis toxicity. Paramedics were called and the patient was brought to the emergency room where he was confirmed to have digitalis toxicity and was quickly treated with digoxin-specific Fab antibody fragments. Web-based monitoring systems helped in the diagnosis of this potentially lethal drug toxicity.

Entities:  

Year:  2009        PMID: 21686562      PMCID: PMC3028227          DOI: 10.1136/bcr.09.2008.0918

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  8 in total

1.  Smart pacemakers join the Web.

Authors: 
Journal:  Harv Heart Lett       Date:  2003-03

2.  [Guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Executive summary].

Authors:  Douglas P Zipes; A John Camm; Martin Borggrefe; Alfred E Buxton; Bernard Chaitman; Martin Fromer; Gabriel Gregoratos; George Klein; Arthur J Moss; Robert J Myerburg; Silvia G Priori; Miguel A Quinones; Dan M Roden; Michael J Silka; Cynthia Tracy
Journal:  Rev Esp Cardiol       Date:  2006-12       Impact factor: 4.753

Review 3.  Electrocardiographic manifestations: digitalis toxicity.

Authors:  G Ma; W J Brady; M Pollack; T C Chan
Journal:  J Emerg Med       Date:  2001-02       Impact factor: 1.484

Review 4.  Recognition and management of digitalis toxicity.

Authors:  R A Kelly; T W Smith
Journal:  Am J Cardiol       Date:  1992-06-04       Impact factor: 2.778

5.  An automated, web-enabled and searchable database system for archiving electrogram and related data from implantable cardioverter defibrillators.

Authors:  W Zong; P Wang; B Leung; G B Moody; R G Mark
Journal:  Comput Cardiol       Date:  2002

6.  Remote monitoring of implantable cardioverter defibrillators: a prospective analysis.

Authors:  Mark H Schoenfeld; Steven J Compton; R Hardwin Mead; Daniel N Weiss; Lou Sherfesee; Jennifer Englund; Luc R Mongeon
Journal:  Pacing Clin Electrophysiol       Date:  2004-06       Impact factor: 1.976

7.  Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization.

Authors:  Renato Pietro Ricci; Loredana Morichelli; Massimo Santini
Journal:  Europace       Date:  2008-01-16       Impact factor: 5.214

Review 8.  Mechanisms, manifestations, and management of digoxin toxicity in the modern era.

Authors:  Jerry L Bauman; Robert J Didomenico; William L Galanter
Journal:  Am J Cardiovasc Drugs       Date:  2006       Impact factor: 3.571

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.