Literature DB >> 15189530

Remote monitoring of implantable cardioverter defibrillators: a prospective analysis.

Mark H Schoenfeld1, Steven J Compton, R Hardwin Mead, Daniel N Weiss, Lou Sherfesee, Jennifer Englund, Luc R Mongeon.   

Abstract

A prospective study evaluating the functionality and ease of use of the Medtronic CareLink Network, "CareLink," was conducted at ten investigational sites. This internet-based remote monitoring service allows clinicians to remotely manage their patients' implantable cardioverter defibrillators (ICDs) and chronic diseases. The network is comprised of a patient monitor, a secure server, and clinician and patient websites. Under clinician direction, patients interrogated their ICDs at home, and transmitted data to secure servers via a standard telephone line. Comprehensive device data and a 10-second presenting rhythm electrogram were captured by the monitor and available for access and review on the clinician website. The information could also be printed using a standard desktop computer with internet access. During this study, patients were asked to transmit device data twice, at least 7 days apart, as scheduled by the clinic. Monitor functionality was assessed, and ease of using the system components was evaluated via questionnaires completed by patients and clinicians following each data transmission and review. Fifty-nine patients (64 +/- 14 years, range 22-85 years) completed 119 transmissions with only 14 calls to the study support center. Clinician review of data transmissions revealed several clinically significant findings, including silent AF discovery, assessment of antiarrhythmic drug efficacy in a previously diagnosed AF patient, previously unobserved atrial undersensing, and ventricular tachycardia. ICD patients found the monitor easy to use. Clinicians were pleased with the performance of the network and the quality of the web-accessed data, and found it comparable to an in-office device interrogation. CareLink is a practical tool for routine device management and may allow timely identification of clinically important issues.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15189530     DOI: 10.1111/j.1540-8159.2004.00524.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  38 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

Review 2.  Strategic choices to reduce implantable cardioverter-defibrillator-related morbidity.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2010-04-20       Impact factor: 32.419

3.  Characteristics of Sprint Fidelis lead failure.

Authors:  R J Beukema; A R Ramdat Misier; P P H M Delnoy; J J J Smit; A Elvan
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

4.  Recollection of pain due to inappropriate versus appropriate implantable cardioverter-defibrillator shocks.

Authors:  Gregory M Marcus; Derrick W Chan; Rita F Redberg
Journal:  Pacing Clin Electrophysiol       Date:  2010-11-15       Impact factor: 1.976

5.  Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.

Authors:  Paul Chun Yih Lim; Audry Shan Yin Lee; Kelvin Chi Ming Chua; Eric Tien Siang Lim; Daniel Thuan Tee Chong; Boon Yew Tan; Kah Leng Ho; Wee Siong Teo; Chi Keong Ching
Journal:  Singapore Med J       Date:  2016-07       Impact factor: 1.858

6.  Remote monitoring in implantable defibrillator therapy.

Authors:  D A M J Theuns; L S Jordaens
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

Review 7.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

8.  Therapeutic implications of automatic home monitoring of implantable cardiac devices.

Authors:  Niraj Varma
Journal:  Curr Treat Options Cardiovasc Med       Date:  2009-10

9.  Can we predict and prevent adverse events related to high-voltage implantable cardioverter defibrillator lead failure?

Authors:  Renato Pietro Ricci; Carlo Pignalberi; Barbara Magris; Stefano Aquilani; Vito Altamura; Loredana Morichelli; Antonio Porfili; Laura Quarta; Fabio Saputo; Massimo Santini
Journal:  J Interv Card Electrophysiol       Date:  2011-09-01       Impact factor: 1.900

10.  "We as Human Beings Get Farther and Farther Apart": the experiences of patients with remote monitoring systems.

Authors:  Abigale L Ottenberg; Keith M Swetz; Luke A Mueller; Samantha Gerhardson; Paul S Mueller
Journal:  Heart Lung       Date:  2013-04-10       Impact factor: 2.210

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.