Literature DB >> 2168439

Indirect immunofluorescence test performance and questionnaire results from the Centers for Disease Control Model Performance Evaluation Program for human immunodeficiency virus type 1 testing.

R N Taylor1, T L Hearn, W O Schalla, R O Valdiserri.   

Abstract

Results from laboratories performing indirect immunofluorescence (IIF) testing for human immunodeficiency virus type 1 antibody and participating in the Centers for Disease Control Model Performance Evaluation Program in 1988 are presented. Approximately 90% of all laboratories receiving specimen panels or questionnaires furnished results to the Centers for Disease Control. In September 1988, 111 reports were received from IIF laboratories from 34 states and nine countries; most of these laboratories did IIF testing in conjunction with other antibody tests. Hospital laboratories were the most common type of laboratory participating in the program. Laboratories that performed IIF employed fewer personnel and performed testing less frequently than did laboratories that performed enzyme immunoassays or Western blot (immunoblot) tests and were likely to use a commercial test kit. Most of the laboratories that referred specimens for IIF testing sent them to the state laboratory. The analytic specificity for the Model Performance Evaluation Program specimens was 98.5% when indeterminate results on a negative specimen were considered correct (negative) and 89.6% when indeterminate results on a negative specimen were considered incorrect; analytic sensitivity was 94.8% when indeterminate results on a positive specimen were correct (positive) and 91.4% when indeterminate results on a positive specimen were considered incorrect. When indeterminate results were considered correct, all types of laboratories (blood bank, state, hospital, independent, and other) had analytic specificities over 96%, and all manufacturers had analytic specificities above 95%. All types of laboratories had analytic sensitivities over 92%, and analytic sensitivities were above 94% for all manufacturers and reagent sources except Cellular Products. Comparison of percentages of correct responses between IIF and Western blot assays on those samples for which there was good agreement on the target interpretation revealed no significant differences. Both individual donor and diluted materials were included in the evaluations; the diluted donor material presented the greatest testing difficulty. Within-survey reproducibility was about 93% overall and by specimen type. Between-survey reproducibility was about 81% for negative and indeterminate specimens and 88.5% for positive specimens, for an overall between-survey reproducibility of 84.3%. Differences in performance were noted when results were compared by type of laboratory and test manufacturer.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2168439      PMCID: PMC268050          DOI: 10.1128/jcm.28.8.1799-1807.1990

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  16 in total

1.  Testing for human immunodeficiency virus.

Authors:  J J Goedert
Journal:  Ann Intern Med       Date:  1986-10       Impact factor: 25.391

2.  Comparison of enzyme immunoassays and an immunofluorescence test for detection of antibody to human immunodeficiency virus in African sera.

Authors:  G Vercauteren; G van der Groen; P Piot
Journal:  Eur J Clin Microbiol       Date:  1987-04       Impact factor: 3.267

Review 3.  A pathogenic retrovirus (HTLV-III) linked to AIDS.

Authors:  S Broder; R C Gallo
Journal:  N Engl J Med       Date:  1984-11-15       Impact factor: 91.245

4.  Testing for antibodies to AIDS-associated retrovirus (HTLV-III/LAV) by indirect fixed cell immunofluorescence: specificity, sensitivity, and applications.

Authors:  M Hedenskog; S Dewhurst; C Ludvigsen; F Sinangil; L Rodriguez; Y T Wu; D J Volsky
Journal:  J Med Virol       Date:  1986-08       Impact factor: 2.327

5.  CDC's Model Performance Evaluation Program: assessment of the quality of laboratory performance for HIV-1 antibody testing.

Authors:  W O Schalla; T L Hearn; R N Taylor; E Eavenson; R O Valdiserri; J D Essien
Journal:  Public Health Rep       Date:  1990 Mar-Apr       Impact factor: 2.792

6.  Evaluation of the indirect immunofluorescence assay as a confirmatory test for detecting antibodies to the human immunodeficiency virus.

Authors:  T M McHugh; D P Stites; C H Casavant; J R Carlson; J Yee; P A McVay; M P Busch; J A Levy
Journal:  Diagn Immunol       Date:  1986

7.  Comparison of indirect immunofluorescence and Western blot for detection of anti-human immunodeficiency virus antibodies.

Authors:  J R Carlson; J Yee; S H Hinrichs; M L Bryant; M B Gardner; N C Pedersen
Journal:  J Clin Microbiol       Date:  1987-03       Impact factor: 5.948

8.  Indirect immunofluorescence assay for antibodies to human immunodeficiency virus.

Authors:  E T Lennette; S Karpatkin; J A Levy
Journal:  J Clin Microbiol       Date:  1987-02       Impact factor: 5.948

9.  Isolation of human T-cell leukemia virus in acquired immune deficiency syndrome (AIDS).

Authors:  R C Gallo; P S Sarin; E P Gelmann; M Robert-Guroff; E Richardson; V S Kalyanaraman; D Mann; G D Sidhu; R E Stahl; S Zolla-Pazner; J Leibowitch; M Popovic
Journal:  Science       Date:  1983-05-20       Impact factor: 47.728

10.  Frequent detection and isolation of cytopathic retroviruses (HTLV-III) from patients with AIDS and at risk for AIDS.

Authors:  R C Gallo; S Z Salahuddin; M Popovic; G M Shearer; M Kaplan; B F Haynes; T J Palker; R Redfield; J Oleske; B Safai
Journal:  Science       Date:  1984-05-04       Impact factor: 47.728

View more
  3 in total

1.  Lignin peroxidase initiates O2-dependent self-propagating chemical reactions which accelerate the consumption of 1-(3',4'-dimethoxyphenyl)propene.

Authors:  R ten Have ; M C Franssen; J A Field
Journal:  Biochem J       Date:  2000-04-15       Impact factor: 3.857

2.  HIV transmission: Women's risk from bisexual men.

Authors:  R W Wood; L E Krueger; T C Pearlman; G Goldbaum
Journal:  Am J Public Health       Date:  1993-12       Impact factor: 9.308

3.  Comparing Multiple Sensitivities and Specificities with Different Diagnostic Criteria: Applications to Sexual Abuse and Sexual Health Research.

Authors:  Q Yu; W Tang; Y Ma; S A Gamble; X M Tu
Journal:  Comput Stat Data Anal       Date:  2008-09       Impact factor: 1.681

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.