Literature DB >> 21683332

Quality of vision after femtosecond laser-assisted descemet stripping endothelial keratoplasty and penetrating keratoplasty: a randomized, multicenter clinical trial.

Yanny Y Y Cheng1, Tom J T P van den Berg, Jan S Schouten, Elisabeth Pels, Robert-Jan Wijdh, Hugo van Cleynenbreugel, Catharina A Eggink, Wilhelmina J Rijneveld, Rudy M M A Nuijts.   

Abstract

PURPOSE: To compare the quality of vision (straylight and contrast sensitivity) after femtosecond laser-assisted Descemet stripping endothelial keratoplasty (FS DSEK) and penetrating keratoplasty (PK).
DESIGN: Prospective, randomized clinical trial.
METHODS: setting: Multicenter (5 ophthalmic centers in The Netherlands). study population: Eighty eyes of 80 patients with corneal endothelial dysfunction were included and were randomized to FS DSEK or PK. observation procedures: FS DSEK and PK. main outcome measures: Straylight, contrast sensitivity, astigmatism, uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and visual symptom score.
RESULTS: Straylight at 12 months was 1.37 ± 0.2 logarithm of straylight for FS DSEK and 1.46 ± 0.2 logarithm of straylight for PK (P = .151). During 12 months of follow-up, there was a significant improvement of straylight and contrast sensitivity after FS DSEK (P < .001) and PK (P < .001). The change of straylight and contrast sensitivity correlated significantly with the change of BSCVA after FS DSEK (r = -0.645; r = 0.580) and PK (r = -0.370; r = 0.659). The visual symptom score was comparable between the 2 groups during the 12 months of follow-up.
CONCLUSIONS: Improvement of straylight and contrast sensitivity was significantly correlated with an improvement of BSCVA. Straylight and contrast sensitivity were improved significantly after FS DSEK and were comparable with those after PK, although BSCVA was slightly better in the PK group.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21683332     DOI: 10.1016/j.ajo.2011.03.012

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  6 in total

1.  Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

Authors:  Daisuke Tomida; Takefumi Yamaguchi; Akiko Ogawa; Yumiko Hirayama; Seika Shimazaki-Den; Yoshiyuki Satake; Jun Shimazaki
Journal:  Jpn J Ophthalmol       Date:  2015-06-02       Impact factor: 2.447

Review 2.  Graft rejection rate and graft failure rate of penetrating keratoplasty (PKP) vs lamellar procedures: a systematic review.

Authors:  Zarique Z Akanda; Abdul Naeem; Elizabeth Russell; Jillian Belrose; Francie F Si; William G Hodge
Journal:  PLoS One       Date:  2015-03-17       Impact factor: 3.240

3.  Clinical features and visual function in a patient with Fish-eye disease: Quantitative measurements and optical coherence tomography.

Authors:  Masanori Kanai; Shizuka Koh; Daisaku Masuda; Masahiro Koseki; Kohji Nishida
Journal:  Am J Ophthalmol Case Rep       Date:  2018-02-24

Review 4.  Endothelial keratoplasty versus penetrating keratoplasty for Fuchs endothelial dystrophy.

Authors:  Mayank A Nanavaty; Xue Wang; Alex J Shortt
Journal:  Cochrane Database Syst Rev       Date:  2014-02-14

5.  Corneal transplantation for Fuchs´ endothelial dystrophy: A comparison of three surgical techniques concerning 10 year graft survival and visual function.

Authors:  Jeroen van Rooij; Elsina H Lucas; Annette J Geerards; Lies Remeijer; Rene Wubbels
Journal:  PLoS One       Date:  2018-10-05       Impact factor: 3.240

6.  Surface quality and endothelial cell viability after femtosecond laser-assisted donor lenticule preparation for endothelial keratoplasty - An in-vitro study.

Authors:  Jeewan S Titiyal; M J Aravind; Manpreet Kaur; Tapas C Nag; Namrata Sharma; Tushar Agarwal; Rajesh Sinha
Journal:  Indian J Ophthalmol       Date:  2020-11       Impact factor: 1.848

  6 in total