Literature DB >> 21682844

Changes in implant stability using different site preparation techniques: twist drills versus piezosurgery. A single-blinded, randomized, controlled clinical trial.

Claudio Stacchi1, Tomaso Vercellotti, Lucio Torelli, Fabio Furlan, Roberto Di Lenarda.   

Abstract

PURPOSE: The objective of the present investigation was to longitudinally monitor stability changes of implants inserted using traditional rotary instruments or piezoelectric inserts, and to follow their variations during the first 90 days of healing.
MATERIALS AND METHODS: A randomized, controlled trial was conducted on 20 patients. Each patient received two identical, adjacent implants in the upper premolar area: the test site was prepared with piezosurgery, and the control site was prepared using twist drills. Resonance frequency analysis measurements were taken by a blinded operator on the day of surgery and after 7, 14, 21, 28, 42, 56, and 90 days.
RESULTS: At 90 days, 39 out of 40 implants were osseointegrated (one failure in the control group). Both groups showed an initial decrease in mean implant stability quotient (ISQ) values: a shift in implant stability to increasing ISQ values occurred after 14 days in the test group and after 21 days in the control group. The lowest mean ISQ value was recorded at 14 days for test implants (97.3% of the primary stability) and at 21 days for the control implants (90.8% of the primary stability). ISQ variations with respect to primary stability differed significantly between the two groups during the entire period of observation: from day 14 to day 42, in particular, the differences were extremely significant (p < .0001). All 39 implants were in function successfully at the visit scheduled 1 year after insertion.
CONCLUSIONS: The findings from this study suggest that ultrasonic implant site preparation results in a limited decrease of ISQ values and in an earlier shifting from a decreasing to an increasing stability pattern, when compared with the traditional drilling technique. From a clinical point of view, implants inserted with the piezoelectric technique demonstrated a short-term clinical success similar to those inserted using twist drills.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21682844     DOI: 10.1111/j.1708-8208.2011.00341.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  15 in total

1.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

2.  Bone Micromorphology and Material Attrition After Sonic, Ultrasonic and Conventional Osteotomies.

Authors:  Ashkan Rashad; Stefan Schwan; Alireza Nasirpour; Inge Schmitz; Henning Hanken; Reinhard E Friedrich; Martin Gosau
Journal:  In Vivo       Date:  2021 May-Jun       Impact factor: 2.155

3.  Healing at implants installed in osteotomies prepared either with a piezoelectric device or drills: an experimental study in dogs.

Authors:  Shigeo Fujiwara; Shingo Kato; Franco Bengazi; Joaquin Urbizo Velez; Margherita Tumedei; Mitsuo Kotsu; Daniele Botticelli
Journal:  Oral Maxillofac Surg       Date:  2020-08-15

4.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

Review 5.  Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review.

Authors:  Rola Muhammed Shadid; Nasrin Rushdi Sadaqah; Sahar Abdo Othman
Journal:  Int J Dent       Date:  2014-07-07

6.  Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips.

Authors:  Alessandro Moro; Giulio Gasparini; Enrico Foresta; Gianmarco Saponaro; Marco Falchi; Lorenzo Cardarelli; Paolo De Angelis; Mario Forcione; Umberto Garagiola; Giuseppe D'Amato; Sandro Pelo
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

7.  The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study.

Authors:  G Falisi; M Severino; C Rastelli; S Bernardi; S Caruso; M Galli; L Lamazza; C Di Paolo
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-03-01

8.  Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

Authors:  Luca Lamazza; Girolamo Garreffa; Domenica Laurito; Marco Lollobrigida; Luigi Palmieri; Alberto De Biase
Journal:  Biomed Res Int       Date:  2016-03-24       Impact factor: 3.411

9.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

10.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.