BACKGROUND: It is important to adjust stem anteversion in cases of excessive femoral version to avoid prosthetic impingement-related complications in total hip arthroplasty. Although modular necks are considered an effective solution, their application in cases with wide variations in femoral anteversion remains to be elucidated. This study aimed to simulate the effects of different modular necks on prevention of prosthetic impingement due to excessive femoral anteversion.
METHODS: We investigated range of motion without prosthetic impingement by collision detection using implant computer-aided design models of the ANCA-Fit system.
FINDINGS: Modular necks could provide an adequate range of motion in cases with up to 60° of femoral anteversion. However, few alternative necks were available in cases with excessive femoral anteversion, while many options could be used for femoral offset and version control in cases with average amounts of femoral anteversion without prosthetic impingement.
INTERPRETATION: We conclude that modular necks might provide a marginal advantage over other options such as cemented, conical or modular stems for cases with an excessively anteverted femur, although they could help to maintain the femoral offset in some cases with average femoral anteversion.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21680069     DOI: 10.1016/j.clinbiomech.2011.05.016

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  CORR Insights®: Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2017-02-24       Impact factor: 4.176

2.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

3.  Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  Sandrine Colas; Assia Allalou; Antoine Poichotte; Philippe Piriou; Rosemary Dray-Spira; Mahmoud Zureik
Journal:  Clin Orthop Relat Res       Date:  2017-02-13       Impact factor: 4.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.