Literature DB >> 21679083

Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis.

Haiwei Li1, Hongshan Zhong, Ke Xu, Ke Yang, Jing Liu, Bingchun Zhang, Feng Zheng, Yonghui Xia, Lili Tan, Duo Hong.   

Abstract

PURPOSE: To determine the efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents (SEBMAS) in restenosis prevention.
METHODS: A balloon-expandable bioabsorbable magnesium alloy stent (BMAS) was created and coated with biodegradable poly(lactic acid-co-trimethylene carbonate) that contained the antiproliferative drug sirolimus (140 ± 40 µg/cm²). Both the uncoated BMAS and the coated SEBMAS were deployed 2 cm apart in balloon-injured infrarenal abdominal aortas of 20 New Zealand white rabbits. The stented aortic segments were removed at 30, 60, 90, and 120 days (5 rabbits per interval) after implantation. The average stent strut sectional area of each group was measured to evaluate the degree of magnesium corrosion and to forecast the biodegradation time profile of the magnesium stent. Histology and histopathology of the sectioned stented aortic segments were performed to evaluate neointima formation, endothelialization, and inflammation.
RESULTS: The SEBMAS degraded gradually after being implanted into the rabbit aorta, and total biocorrosion occurred after ~120 days. In all groups, the lumen area was significantly greater, but the neointimal area was significantly smaller in SEBMAS segments compared with the uncoated BMAS segments (p < 0.05) at all time points. There was no significant difference in the injury or inflammation scores between the groups. Endothelialization was delayed at 30 days in the SEBMAS segments vs. the uncoated BMAS segments.
CONCLUSION: SEBMAS further reduces intimal hyperplasia and improves the lumen area when compared to uncoated BMAS; however, it delays vascular healing and endothelialization.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21679083     DOI: 10.1583/10-3353.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  9 in total

Review 1.  The effects of novel, bioresorbable scaffolds on coronary vascular pathophysiology.

Authors:  Michael J Lipinski; Ricardo O Escarcega; Thibault Lhermusier; Ron Waksman
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

2.  Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery.

Authors:  Hong-Kai Cui; Fen-Bao Li; Ying-Chang Guo; Yong-Li Zhao; Rui-Fang Yan; Wu Wang; Yong-Dong Li; Yong-Li Wang; Guang-Yin Yuan
Journal:  Eur Radiol       Date:  2017-01-26       Impact factor: 5.315

3.  Sirolimus-eluting dextran and polyglutamic acid hybrid coatings on AZ31 for stent applications.

Authors:  Jun Ma; Nan Zhao; Donghui Zhu
Journal:  J Biomater Appl       Date:  2015-07-21       Impact factor: 2.646

Review 4.  Magnesium-based materials in orthopaedics: material properties and animal models.

Authors:  Xirui Jing; Qiuyue Ding; Qinxue Wu; Weijie Su; Keda Yu; Yanlin Su; Bing Ye; Qing Gao; Tingfang Sun; Xiaodong Guo
Journal:  Biomater Transl       Date:  2021-09-28

5.  Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

Authors:  Jun Ma; Nan Zhao; Lexxus Betts; Donghui Zhu
Journal:  J Mater Sci Technol       Date:  2015-12-24       Impact factor: 8.067

6.  Endothelialization of novel magnesium-rare earth alloys with fluoride and collagen coating.

Authors:  Nan Zhao; Benjamin Workman; Donghui Zhu
Journal:  Int J Mol Sci       Date:  2014-03-25       Impact factor: 5.923

7.  In vivo response of AZ31 alloy as biliary stents: a 6 months evaluation in rabbits.

Authors:  Yang Liu; Shengmin Zheng; Nan Li; Huahu Guo; Yufeng Zheng; Jirun Peng
Journal:  Sci Rep       Date:  2017-01-13       Impact factor: 4.379

8.  Degraded and osteogenic properties of coated magnesium alloy AZ31; an experimental study.

Authors:  Jinpeng Zhuang; Yongbin Jing; Yaming Wang; Jinghuai Zhang; Huanxin Xie; Jinglong Yan
Journal:  J Orthop Surg Res       Date:  2016-03-14       Impact factor: 2.359

9.  In vitro and in vivo evaluation of a novel bioresorbable magnesium scaffold with different surface modifications.

Authors:  Roman Menze; Eric Wittchow
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2021-01-01       Impact factor: 3.368

  9 in total