Literature DB >> 21670900

Corneal biomechanical evaluation in healthy thin corneas compared with matched keratoconus cases.

Bruno Machado Fontes1, Renato Ambrósio, Guillermo Coca Velarde, Walton Nosé.   

Abstract

PURPOSE: To evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in healthy eyes with a central corneal thickness (CCT) < 505 µm with CH and CRF in gender-, age-, and CCT-matched keratoconus cases, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups.
METHODS: Prospective, comparative case series. In total 46 eyes from 30 healthy patients with CCT < 505 µm, and 42 eyes from 30 CCT-, gender- and age-matched keratoconus cases were enrolled. Biomechanical metrics (CH and CRF) were measured using the Ocular Response Analyzer (ORA) and then compared. A receiver operating characteristic (ROC) curve was used to identify cut-off points to maximize the sensitivity and specificity for discriminating between the groups.
RESULTS: The CCT was 485.96 ± 17.61 µm (range, 438 - 505) in healthy thin corneas and 483.64 ± 16.19 µm (range, 452 - 505) in keratoconus; p=0.5225. CH was 8.63 ± 1.23 mmHg (range, 5.95 - 12.2) and 8.07 ± 1.17 mmHg (range, 4.9 - 9.85), respectively; p=0.0312. CRF was 8.43 ± 1.29 mmHg (range, 5.45 - 11.10) and 7.22 ± 1.34 mmHg (range, 4.7 - 9.45), respectively; p<0.001. ROC curve analysis showed a poor overall predictive accuracy of CH (cut-off, 8.95 mmHg; sensitivity, 63%; specificity, 23.8%; test accuracy, 44.30%) and CRF (cut-off, 7.4 mmHg; sensitivity, 28.3%; specificity, 40.5%; test accuracy, 34.12%) for detecting keratoconus in the eyes studied.
CONCLUSION: CH and CRF were statistically lower in keratoconus than in healthy thin corneas. However, CH and CRF offered very low sensitivity and specificity for discriminating the groups.

Entities:  

Mesh:

Year:  2011        PMID: 21670900     DOI: 10.1590/s0004-27492011000100003

Source DB:  PubMed          Journal:  Arq Bras Oftalmol        ISSN: 0004-2749            Impact factor:   0.872


  13 in total

1.  Short-term effects of overnight orthokeratology on corneal epithelial permeability and biomechanical properties.

Authors:  Thao N Yeh; Harry M Green; Yixiu Zhou; Julie Pitts; Britney Kitamata-Wong; Sophia Lee; Shiyin L Wang; Meng C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-06       Impact factor: 4.799

2.  Corneal Deformation Response and Ocular Geometry: A Noninvasive Diagnostic Strategy in Marfan Syndrome.

Authors:  Lauren C Beene; Elias I Traboulsi; Ibrahim Seven; Matthew R Ford; Abhijit Sinha Roy; Robert S Butler; William J Dupps
Journal:  Am J Ophthalmol       Date:  2015-10-24       Impact factor: 5.258

3.  Detection ability of corneal biomechanical parameters for early diagnosis of ectasia.

Authors:  Mohammad-Reza Sedaghat; Hamed Momeni-Moghaddam; Javad Heravian; Atiyeh Ansari; Helia Shayanfar; Majid Moshirfar
Journal:  Eye (Lond)       Date:  2022-08-29       Impact factor: 4.456

4.  Impaired corneal biomechanical properties and the prevalence of keratoconus in mitral valve prolapse.

Authors:  Emine Kalkan Akcay; Murat Akcay; Betul Seher Uysal; Pinar Kosekahya; Abdullah Nabi Aslan; Mehtap Caglayan; Cemal Koseoglu; Fatma Yulek; Nurullah Cagil
Journal:  J Ophthalmol       Date:  2014-04-17       Impact factor: 1.909

5.  Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates.

Authors:  Zofia Pniakowska; Piotr Jurowski
Journal:  Indian J Ophthalmol       Date:  2016-02       Impact factor: 1.848

6.  Ocular response analyzer parameters in healthy, keratoconus suspect and manifest keratoconus eyes.

Authors:  Mehrdad Mohammadpour; Ifa Etesami; Zahra Yavari; Mohammad Naderan; Fatemeh Abdollahinia; Mahmoud Jabbarvand
Journal:  Oman J Ophthalmol       Date:  2015 May-Aug

7.  Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.

Authors:  Renato Ambrósio; Fernando Faria Correia; Bernardo Lopes; Marcella Q Salomão; Allan Luz; Daniel G Dawson; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Cynthia J Roberts
Journal:  Open Ophthalmol J       Date:  2017-07-31

8.  In vivo measurement of regional corneal tangent modulus.

Authors:  Ying Hon; Guo-Zhen Chen; Shu-Hao Lu; David Cc Lam; Andrew Kc Lam
Journal:  Sci Rep       Date:  2017-11-02       Impact factor: 4.379

9.  Spatially-resolved Brillouin spectroscopy reveals biomechanical abnormalities in mild to advanced keratoconus in vivo.

Authors:  Peng Shao; Amira M Eltony; Theo G Seiler; Behrouz Tavakol; Roberto Pineda; Tobias Koller; Theo Seiler; Seok-Hyun Yun
Journal:  Sci Rep       Date:  2019-05-16       Impact factor: 4.379

10.  Corneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature.

Authors:  Majid Moshirfar; Jason N Edmonds; Nicholas L Behunin; Steven M Christiansen
Journal:  Oman J Ophthalmol       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.