Literature DB >> 21669450

Ultrasonic system for accurate distance measurement in the air.

Tomasz J Licznerski1, Jarosław Jaroński, Dariusz Kosz.   

Abstract

This paper presents a system that accurately measures the distance travelled by ultrasound waves through the air. The simple design of the system and its obtained accuracy provide a tool for non-contact distance measurements required in the laser's optical system that investigates the surface of the eyeball. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Year:  2011        PMID: 21669450     DOI: 10.1016/j.ultras.2011.05.011

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  9 in total

1.  An ultrasound-based liquid pressure measurement method in small diameter pipelines considering the installation and temperature.

Authors:  Xue Li; Zhengxiang Song
Journal:  Sensors (Basel)       Date:  2015-04-09       Impact factor: 3.576

2.  Wavelet representation of the corneal pulse for detecting ocular dicrotism.

Authors:  Tomasz Melcer; Monika E Danielewska; D Robert Iskander
Journal:  PLoS One       Date:  2015-04-23       Impact factor: 3.240

3.  Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor.

Authors:  Hongjuan Zhang; Yu Wang; Xu Zhang; Dong Wang; Baoquan Jin
Journal:  Sensors (Basel)       Date:  2016-06-13       Impact factor: 3.576

4.  Corneal pulsation and biomechanics during induced ocular pulse. An ex-vivo pilot study.

Authors:  Maja M Rogala; Daniel Lewandowski; Jerzy Detyna; Agnieszka Antończyk; Monika E Danielewska
Journal:  PLoS One       Date:  2020-02-13       Impact factor: 3.240

5.  Development of a photochemical thrombosis investigation system to obtain a rabbit ischemic stroke model.

Authors:  Yoonhee Kim; Yoon Bum Lee; Seung Kuk Bae; Sung Suk Oh; Jong-Ryul Choi
Journal:  Sci Rep       Date:  2021-03-11       Impact factor: 4.379

6.  The effect of changes in cardiovascular activity on corneal biomechanics and pulsation in rabbits.

Authors:  Agnieszka Antończyk; Monika E Danielewska; Dominika Kubiak-Nowak; Wojciech Borawski; Zdzisław Kiełbowicz
Journal:  Sci Rep       Date:  2020-12-17       Impact factor: 4.379

7.  Relationship Between the Parameters of Corneal and Fundus Pulse Signals Acquired With a Combined Ultrasound and Laser Interferometry Technique.

Authors:  Monika E Danielewska; Alina Messner; René M Werkmeister; Michał M Placek; Valentin Aranha Dos Santos; Marek Rękas; Leopold Schmetterer
Journal:  Transl Vis Sci Technol       Date:  2019-08-01       Impact factor: 3.283

8.  Glaucomatous and age-related changes in corneal pulsation shape. The ocular dicrotism.

Authors:  Monika E Danielewska; Patrycja Krzyżanowska-Berkowska; D Robert Iskander
Journal:  PLoS One       Date:  2014-07-17       Impact factor: 3.240

9.  Deformation Monitoring of Metro Tunnel with a New Ultrasonic-Based System.

Authors:  Dong-Sheng Xu; Yu-Meng Zhao; Hua-Bei Liu; Hong-Hu Zhu
Journal:  Sensors (Basel)       Date:  2017-08-01       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.