Literature DB >> 21668655

Automated vs. manual cerebrospinal fluid cell counts: a work and cost analysis comparing the Sysmex XE-5000 and the Fuchs-Rosenthal manual counting chamber.

M Zimmermann1, K Ruprecht, F Kainzinger, F L Heppner, A Weimann.   

Abstract

INTRODUCTION: Cerebrospinal fluid (CSF) cell counts are traditionally performed by manual microscopy using the Fuchs-Rosenthal counting chamber. This procedure is time-, labour- and cost-intensive and requires experienced laboratory staff.
METHODS: The Sysmex XE-5000 haematology analyzer offers a channel to quantify the total cell count of body fluids. We compared technical sensitivity and specificity, intra-assay variability, turn-around time (TAT) and costs for the determination of CSF cell counts between both methods.
RESULTS: The mean coefficients of variation (CV) for total cell counts in CSF of the Fuchs-Rosenthal chamber and the XE-5000 were 15.2% (range: 2.8-47.5%) and 12.5% (range: 1.9-50.6%). Setting the Fuchs-Rosenthal chamber as 'gold standard', our results revealed a sensitivity of 100% and a specificity of 75% for the XE-5000 to detect a pathological cell count (≥ 6 cells/μL), whereas the sensitivity and specificity to detect a severely pathological cell count (≥ 20 cells/μL) were 100% for both. Bland and Altman analysis revealed slightly higher cell counts with the XE-5000. The approximate duration of a single CSF cell count analysis was 635 s for the manual vs. 85 s for the automated method. Total analytical performance costs for the counting chamber were 6.74 EUR per mean analysis and 1.22 EUR for the XE-5000.
CONCLUSION: Our study revealed a lower mean CV for the total cell count for the XE-5000 method. The fully automated CSF cell count results in a 7.5-fold reduction in TAT and leads to a significant decrease in total analytical performance costs.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21668655     DOI: 10.1111/j.1751-553X.2011.01339.x

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  9 in total

1.  Use of the Sysmex XT-4000i hematology analyzer in the differentiation of cerebrospinal fluid cells in children.

Authors:  Beata Zelazowska-Rutkowska; Janusz Zak; Malgorzata Wojtkowska; Justyna Zaworonek; Bogdan Cylwik
Journal:  J Clin Lab Anal       Date:  2018-11-28       Impact factor: 2.352

2.  Evaluation of Sysmex XN-1000 hematology analyzer for cell count and screening of malignant cells of serous cavity effusion.

Authors:  Weiyi Xu; Qian Yu; Lixia Xie; Baode Chen; Ling Zhang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

3.  Effect of sample processing and time delay on cell count and chemistry tests in cerebrospinal fluid collected from drainage systems.

Authors:  Ana Mlinarić; Željka Vogrinc; Zrinka Drenšek
Journal:  Biochem Med (Zagreb)       Date:  2018-10-15       Impact factor: 2.313

4.  Improvement of cell counting method for Neubauer counting chamber.

Authors:  Minghao Zhang; Lingui Gu; Peihua Zheng; Zhixin Chen; Xinqi Dou; Qizhong Qin; Xiaozhong Cai
Journal:  J Clin Lab Anal       Date:  2019-08-30       Impact factor: 2.352

5.  Screening for malignant tumor cells in serous effusions with an automatic hematology analyzer using a novel diagnostic algorithm.

Authors:  Dehua Sun; Xinru Mao; Taixue An; Xiaojing He; Kai Qiu; Yuhong Luo; Zheyuan Qin; Yongjian He; Tie Xiong; Houmei Feng; Jin Li; Lei Zheng
Journal:  Ann Transl Med       Date:  2022-03

6.  Automated and manual microscopic analyses for leukocyte differential counts in exudative pleural effusions: Real-world disagreement and clinical application.

Authors:  Jaehee Lee; Yu Kyung Kim; Ji Eun Park; Yong Hoon Lee; Sun Ha Choi; Hyewon Seo; Seung Soo Yoo; Shin Yup Lee; Seung-Ick Cha; Jae Yong Park; Chang Ho Kim
Journal:  Medicine (Baltimore)       Date:  2022-09-16       Impact factor: 1.817

7.  Automated Analysis of Cerebrospinal Fluid Cells Using Commercially Available Blood Cell Analysis Devices-A Critical Appraisal.

Authors:  Manfred Wick; Catharina C Gross; Hayrettin Tumani; Brigitte Wildemann; Martin Stangel
Journal:  Cells       Date:  2021-05-18       Impact factor: 6.600

8.  Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

Authors:  Hiroyuki Takemura; Tomohiko Ai; Konobu Kimura; Kaori Nagasaka; Toshihiro Takahashi; Koji Tsuchiya; Haeun Yang; Aya Konishi; Kinya Uchihashi; Takashi Horii; Yoko Tabe; Akimichi Ohsaka
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

9.  Current Variation in Joint Aspiration Practice for the Evaluation of Pediatric Septic Arthritis.

Authors:  K Aaron Shaw; Ryan Sanborn; Benjamin Shore; Walter Truong; Joshua S Murphy
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-09
  9 in total