Approaching a decade of cryo catheter ablation for type 1 atrial flutter-a meta-analysis and systematic review.

Peter Andrew1, Yasir Hamad, Sandra Jerat, Annibale Montenero, Stephen O'Connor.   

Abstract

PURPOSE: Despite increasingly widespread use of cryo catheter ablation (CCA) in clinical practice, current ACC/AHA/ESC guidelines for management of supraventricular arrhythmias cite only radiofrequency catheter ablation (RFCA) as first-line treatment for type 1 atrial flutter (AFL). We performed a meta-analysis of efficacy and procedure outcomes from randomized controlled clinical trials comparing CCA with RFCA for type 1 AFL. A systematic review of non-randomized, single-arm clinical studies of CCA for type 1 AFL was also done.
METHODS: An English language search of Medline, Cochrane, Embase, and an extensive bibliography search from January 2000 to May 2010 was conducted. Inclusion/exclusion criteria were met by six randomized clinical trials for meta-analysis (n = 341) and 13 non-randomized, single-arm clinical studies for systematic review (n = 763). Four primary outcomes were analyzed, namely, percent of patients with bidirectional conduction block (BCB) at procedure, proportion of patients who were asymptomatic during follow-up, procedure time, and fluoroscopy time.
RESULTS: Random effect analyses for CCA versus RFCA favored the latter ablation modality for percent of patients with BCB at procedure (84.3% vs. 93.3%; OR = 0.51; p = 0.14). A similar proportion of patients were asymptomatic during follow-up (85.5% vs. 87.3%; OR = 0.68; p = 0.53). A significantly longer procedure time was determined for CCA (171.7 min vs. 134.5 min; Std diff means = 0.57; p < 0.001), but fluoroscopy time was similar for both (27.5 vs. 27.3 min; Std diff means = 0.12; p = 0.28). Sensitivity analyses revealed a shift in favor of CCA with large tip size catheters only versus RFCA for long-term effectiveness (OR = 1.5; p = 0.09).
CONCLUSIONS: Results from this meta-analysis and systematic review do not generally favor one ablation modality over another for treatment of type 1 AFL. Indeed, there is higher percent BCB at procedure and shorter procedure time with RFCA. However, chronic success and fluoroscopy time were similar for both ablation modalities. Ultimately, investigator experience, catheter costs, and patient preference may sway device selection in clinical practice.

Entities:  

Mesh:

Year:  2011        PMID: 21667098     DOI: 10.1007/s10840-011-9582-0

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  39 in total

Review 1.  Approaches to heterogeneity in meta-analysis.

Authors:  D B Petitti
Journal:  Stat Med       Date:  2001-12-15       Impact factor: 2.373

2.  Low clinical recurrence and procedure benefits following treatment of common atrial flutter by electrogram-guided hot spot focal cryoablation.

Authors:  Annibale S Montenero; Nicola Bruno; Andrea Antonelli; Daniele Mangiameli; Luca Barbieri; Francesco Zumbo; Peter Andrew
Journal:  J Interv Card Electrophysiol       Date:  2006-03       Impact factor: 1.900

3.  Comparison between a 7 French 6 mm tip cryothermal catheter and a 9 French 8 mm tip cryothermal catheter for cryoablation treatment of common atrial flutter.

Authors:  Annibale S Montenero; Nicola Bruno; Andrea Antonelli; Daniele Mangiameli; Luca Barbieri; Peter Andrew; Francesco Zumbo
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

4.  Performance of a new cardiac cryoablation system in the treatment of cavotricuspid valve isthmus-dependent atrial flutter.

Authors:  James P Daubert; Robert H Hoyt; Roy John; Larry Chinitz; David T Martin; Christopher Fellows; Gregory Feld; William Pelkey; Ruchir Sehra
Journal:  Pacing Clin Electrophysiol       Date:  2005-01       Impact factor: 1.976

5.  Long-term efficacy of cryo catheter ablation for the treatment of atrial flutter: results from a repeat electrophysiologic study.

Authors:  Annibale S Montenero; Nicola Bruno; Andrea Antonelli; Daniele Mangiameli; Luca Barbieri; Peter Andrew; Olive Murphy; Stephen O'Connor; Francesco Zumbo
Journal:  J Am Coll Cardiol       Date:  2005-02-15       Impact factor: 24.094

Review 6.  Meta-analysis of ablation of atrial flutter and supraventricular tachycardia.

Authors:  Peter Spector; Matthew R Reynolds; Hugh Calkins; Manu Sondhi; Yingxin Xu; Amber Martin; Catherine J Williams; Isabella Sledge
Journal:  Am J Cardiol       Date:  2009-09-01       Impact factor: 2.778

7.  Acute and long-term efficacy and safety of catheter cryoablation of the cavotricuspid isthmus for treatment of type 1 atrial flutter.

Authors:  Gregory K Feld; James P Daubert; Raul Weiss; William M Miles; William Pelkey
Journal:  Heart Rhythm       Date:  2008-03-21       Impact factor: 6.343

8.  Improved Flutter Ablation Outcomes Using a 10mm-tip Ablation Catheter.

Authors:  Tiago Luiz Luz Leiria; Giuliano Becker; Teresa Kus; Vidal Essebag; Tomy Hadjis; Marcio Lerch Sturmer
Journal:  Indian Pacing Electrophysiol J       Date:  2010-12-26

9.  Long term outcome of cavotricuspid isthmus cryoablation for the treatment of common atrial flutter in 180 patients: a single center experience.

Authors:  Wendel Moreira; Carl Timmermans; Hein J J Wellens; Yuka Mizusawa; David Perez; Suzanne Philippens; Luz-Maria Rodriguez
Journal:  J Interv Card Electrophysiol       Date:  2008-01-31       Impact factor: 1.900

10.  Meta-analysis: neither quick nor easy.

Authors:  Nancy G Berman; Robert A Parker
Journal:  BMC Med Res Methodol       Date:  2002-08-09       Impact factor: 4.615

View more
  2 in total

1.  Efficacy comparison between cryoablation and radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter: a meta-analysis.

Authors:  Yi-He Chen; Hui Lin; Cheng-Long Xie; Xiao-Ting Zhang; Yi-Gang Li
Journal:  Sci Rep       Date:  2015-06-03       Impact factor: 4.379

2.  Single-view geometric calibration for C-arm inverse geometry CT.

Authors:  Jordan M Slagowski; David A P Dunkerley; Charles R Hatt; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.