Literature DB >> 15683482

Performance of a new cardiac cryoablation system in the treatment of cavotricuspid valve isthmus-dependent atrial flutter.

James P Daubert1, Robert H Hoyt, Roy John, Larry Chinitz, David T Martin, Christopher Fellows, Gregory Feld, William Pelkey, Ruchir Sehra.   

Abstract

We sought to evaluate prospectively the safety and efficacy of cryothermal energy to ablate typical atrial flutter (AFL). Ablation of cardiac tissue using cryothermal energy has recently been developed as an alternative to radiofrequency energy, which may offer certain advantages in the treatment of AFL. This prospective, multicenter nonrandomized study of a new catheter-based system for the treatment of cavotricuspid isthmus (CTI)-dependent AFL enrolled patients between 18 and 75 years of age. The CTI dependence of AFL was confirmed at electrophysiologic study with activation mapping and/or entrainment. Patients with atrial septal defect, recent myocardial infarction, left ventricular ejection fraction <0.30, or prior AFL ablation were excluded. Cryoablation of AFL was performed in 48 patients from 11 centers. The procedure was immediately successful in 45 patients (94%), and effective in 30 of 40 patients with complete data available at 6 months. Cryoablation is a promising new treatment of CTI-dependent AFL refractory to medical therapy. Further improvements in catheter design and intravascular sheaths will be tested in a larger multicenter trial.

Entities:  

Mesh:

Year:  2005        PMID: 15683482     DOI: 10.1111/j.1540-8159.2005.00094.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

Review 1.  Approaching a decade of cryo catheter ablation for type 1 atrial flutter-a meta-analysis and systematic review.

Authors:  Peter Andrew; Yasir Hamad; Sandra Jerat; Annibale Montenero; Stephen O'Connor
Journal:  J Interv Card Electrophysiol       Date:  2011-06-11       Impact factor: 1.900

2.  Ablation for atrial fibrillation: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-03-01

3.  Acute success and short-term follow-up of catheter ablation of isthmus-dependent atrial flutter; a comparison of 8 mm tip radiofrequency and cryothermy catheters.

Authors:  A S Thornton; P Janse; M Alings; M F Scholten; J M Mekel; M Miltenburg; E Jessurun; L Jordaens
Journal:  J Interv Card Electrophysiol       Date:  2008-03-25       Impact factor: 1.900

  3 in total