Abstract
Recent developments in multi-functional nanoparticles offer a great potential for targeted delivery of therapeutic compounds and imaging contrast agents to specific cell types, in turn, enhancing therapeutic effect and minimizing side effects. Despite the promise, site specific delivery carriers have not been translated into clinical reality. In this study, we have developed long circulating liposomes with the outer surface decorated with thioated oligonucleotide aptamer (thioaptamer) against E-selectin (ESTA) and evaluated the targeting efficacy and PK parameters. In vitro targeting studies using Human Umbilical Cord Vein Endothelial Cell (HUVEC) demonstrated efficient and rapid uptake of the ESTA conjugated liposomes (ESTA-lip). In vivo, the intravenous administration of ESTA-lip resulted in their accumulation at the tumor vasculature of breast tumor xenografts without shortening the circulation half-life. The study presented here represents an exemplary use of thioaptamer and liposome and opens the door to testing various combinations of thioaptamer and nanocarriers that can be constructed to target multiple cancer types and tumor components for delivery of both therapeutics and imaging agent.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21666286 PMCID: PMC3248173 DOI: 10.18632/oncotarget.261
Source DB: PubMed Journal: Oncotarget ISSN: 1949-2553
Figure 1Physico-chemical properties of ESTA conjugated liposomes
(A) Scheme of TA conjugation to liposome. (B) Quantification of ESTA conjugation on the liposomes. Fluorescence intensity of Cy3-labeled ESTA was plotted against ESTA concentration. Using the standard curve the number of ESTA molecules on ESTA-lip was estimated based on fluorescence measurement. (C) Size and charge of the liposomes. The size of the liposomes was measured using a dynamic light scattering (DLS) and the surface charge was measured by zeta potential. (D) FTIR spectrum of the non labeled-liposomes and ESTA-lips.
Figure 2E-selectin dependent binding of ESTA-lip on E-selectin expressing cells
(A) Induction of E-selectin expression on the HUVEC cells. HUVEC were stimulated with TNF-α (10 ng/ml) for 4 hours. Cells were dissociated with 5mM EDTA and then incubated with FITC labeled E-selectin antibody. Surface fluorescence was measured by flow cytometry and averaged for three separate experiments. (B) ESTA-lip binding to the HUVEC expressing E-selectin. HUVEC was incubated with TNF-α (10 ng/ml) for 3 hours to induce E-selectin expression. The cells were further incubated with Cy3-ESTA-lip-FITC (10 nM) for 2 hours. All images were captured at the same exposure condition for comparison. The final images shown are representative images (at the final magnification: x600) from five random fields of at least three independent experiments. Blue, Hoechst 33342; Red, ESTA; Green, FITC-lip. (C) Immunohistochemical analysis for E-selectin expression on the vasculature of mouse bearing breast xenograft tumor derived from MDA-MB-231. ESTA-lip-Rhodamine were intravenously injected and the tumor was dissected 5 hr after the injection and frozen sections were generated to identify the localization of the liposomes by using fluorescent microscope. (D) ESTA-lip accumulation in tumor parenchyma after 48 hr after the injection. Red, lip-Rhodamine; Blue, Hoechst 33342.
| Kel (hr−1)a | T1/2 (hr)b | Vd (mL)c | AUC (mg.hr/mL)e | CL (mL/hr)d | |
|---|---|---|---|---|---|
| a The elimination rate constant (kel) was obtained from the linear regression plot of the log Cp vs time curves. bThe half life (T1/2) was calculated using the formula: T(1/2)= 0.693/kel. cVolume of distribution (Vd) was calculated using the formula: Vd= dose/Co, where Co is the extrapolated initial concentration. dArea under the curve was calculated from the formula: AUC= Co/Kel, eThe Clearance (CL) was calculated using the formula: CL= Kel × Vd | |||||
| PEG-lip | 0.030 ± 0.004 | 24 ± 4 | 4.2 ± 0.2 | 24848 ± 4897 | 0.12 ± 0.03 |