Literature DB >> 21662838

Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers.

J Bobacka1.   

Abstract

Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.

Entities:  

Year:  1999        PMID: 21662838     DOI: 10.1021/ac990497z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  48 in total

1.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

2.  Evidence of a water layer in solid-contact polymeric ion sensors.

Authors:  Roland De Marco; Jean-Pierre Veder; Graeme Clarke; Andrew Nelson; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  Phys Chem Chem Phys       Date:  2007-10-19       Impact factor: 3.676

3.  Elimination of undesirable water layers in solid-contact polymeric ion-selective electrodes.

Authors:  Jean-Pierre Veder; Roland De Marco; Graeme Clarke; Ryan Chester; Andrew Nelson; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2008-08-01       Impact factor: 6.986

4.  Two-dimensional MXene nanosheets (types Ti3C2Tx and Ti2CTx) as new ion-to-electron transducers in solid-contact calcium ion-selective electrodes.

Authors:  Yuzhou Shao; Yao Yao; Chengmei Jiang; Fengnian Zhao; Xiaoxue Liu; Yibin Ying; Jianfeng Ping
Journal:  Mikrochim Acta       Date:  2019-11-07       Impact factor: 5.833

5.  Multi-analyte biochip (MAB) based on all-solid-state ion-selective electrodes (ASSISE) for physiological research.

Authors:  Wan W Amani Wan Salim; Michael A Zeitchek; Andrew C Hermann; Antonio J Ricco; Ming Tan; Florian Selch; Erich Fleming; Brad M Bebout; Mamoun M Bader; Aeraj Ul Haque; D Marshall Porterfield
Journal:  J Vis Exp       Date:  2013-04-18       Impact factor: 1.355

6.  Synthesis and Characterization of High Integrity Solid-Contact Polymeric Ion Sensors.

Authors:  Roland De Marco; Elaine Jee; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  J Solid State Electrochem       Date:  2009-01-01       Impact factor: 2.647

7.  Effects of architecture and surface chemistry of three-dimensionally ordered macroporous carbon solid contacts on performance of ion-selective electrodes.

Authors:  Melissa A Fierke; Chun-Ze Lai; Philippe Bühlmann; Andreas Stein
Journal:  Anal Chem       Date:  2010-01-15       Impact factor: 6.986

8.  Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.

Authors:  Wei Gao; Sam Emaminejad; Hnin Yin Yin Nyein; Samyuktha Challa; Kevin Chen; Austin Peck; Hossain M Fahad; Hiroki Ota; Hiroshi Shiraki; Daisuke Kiriya; Der-Hsien Lien; George A Brooks; Ronald W Davis; Ali Javey
Journal:  Nature       Date:  2016-01-28       Impact factor: 49.962

9.  All solid-state miniaturized potentiometric sensors for flunitrazepam determination in beverages.

Authors:  Mahmoud A Tantawy; Ekram H Mohamed; Ali M Yehia
Journal:  Mikrochim Acta       Date:  2021-05-19       Impact factor: 5.833

10.  The Origin of the Non-Constancy of the Bulk Resistance of Ion-Selective Electrode Membranes within the Nernstian Response Range.

Authors:  Valentina Keresten; Elena Solovyeva; Konstantin Mikhelson
Journal:  Membranes (Basel)       Date:  2021-05-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.